Your browser doesn't support javascript.
loading
An in vitro comparison of the shear bond strength of a resin-reinforced glass ionomer cement and a composite adhesive for bonding orthodontic brackets.
Movahhed, Hassan Z; Ogaard, Bjørn; Syverud, Morten.
Afiliação
  • Movahhed HZ; Department of Orthodontics, Faculty of Dentistry, University of Oslo, Norway .
Eur J Orthod ; 27(5): 477-83, 2005 Oct.
Article em En | MEDLINE | ID: mdl-16043469
ABSTRACT
The shear bond strength (SBS) of a light-cured, resin-reinforced glass ionomer and a composite adhesive in combination with a self-etching primer was compared after different setting times to evaluate when orthodontic wires could be placed. Additionally, the fracture site after debonding was assessed using the Adhesive Remnant Index (ARI). Eighty freshly extracted human premolars were used. Twenty teeth were randomly assigned to each of four groups (1) brackets bonded with Transbond XT with a Transbond Plus etching primer and debonded within 5 minutes; (2) brackets bonded with Fuji Ortho LC and debonded within 5 minutes; (3) brackets bonded as for group 1 and debonded within 15 minutes; (4) brackets bonded as for group 2 and debonded within 15 minutes. The SBS of each sample was determined with an Instron machine. The mean SBS were, respectively (1) 8.8 +/- 2 MPa; (2) 6.6 +/- 2.5 MPa; (3) 11 +/- 1.6 MPa and (4) 9.6 +/- 1.6 MPa. Interpolating the cumulative fracture probability by means of a Weibull analysis, the 10 per cent probabilities of fracture for the groups were found to be attained for shear stresses of 6.1, 3.1, 8.3 and 7.1 MPa, respectively. Chi-square testing of the ARI scores revealed that the nature of the remnant did not vary significantly with time, but the type of bonding material could generally be distinguished in leaving more or less than 10 per cent of bonding material on the tooth. After debonding, the Transbond system was likely to leave adhesive on at least 10 per cent of the bonded area of the tooth. The present findings indicate that brackets bonded with either Transbond XT in combination with Transbond Plus etching primer and Fuji Ortho LC had adequate bond strength at 5 minutes and were even stronger 15 minutes after initial bonding.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Colagem Dentária / Braquetes Ortodônticos / Cimentos de Resina / Cimentos de Ionômeros de Vidro Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Ano de publicação: 2005 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Colagem Dentária / Braquetes Ortodônticos / Cimentos de Resina / Cimentos de Ionômeros de Vidro Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Ano de publicação: 2005 Tipo de documento: Article