Your browser doesn't support javascript.
loading
Gated cardiac 13N-NH3 PET for assessment of left ventricular volumes, mass, and ejection fraction: comparison with electrocardiography-gated 18F-FDG PET.
Khorsand, Aliasghar; Graf, Senta; Eidherr, Harald; Wadsak, Wolfgang; Kletter, Kurt; Sochor, Heinz; Schuster, Ernst; Porenta, Gerold.
Afiliação
  • Khorsand A; Department of Cardiology, Medical University of Vienna, Vienna, Austria. aliasghar.khorsand@meduniwien.ac.at
J Nucl Med ; 46(12): 2009-13, 2005 Dec.
Article em En | MEDLINE | ID: mdl-16330564
UNLABELLED: The purpose of this study was to evaluate myocardial electrocardiography (ECG)-gated 13N-ammonia (13N-NH3) PET for the assessment of cardiac end-diastolic volume (EDV), cardiac end-systolic volume (ESV), left ventricular (LV) myocardial mass (LVMM), and LV ejection fraction (LVEF) with gated 18F-FDG PET as a reference method. METHODS: ECG-gated 13N-NH3 and 18F-FDG scans were performed for 27 patients (23 men and 4 women; mean+/-SD age, 55+/-15 y) for the evaluation of myocardial perfusion and viability. For both 13N-NH3 and 18F-FDG studies, a model-based image analysis tool was used to estimate endocardial and epicardial borders of the left ventricle on a set of short-axis images and to calculate values for EDV, ESV, LVEF, and LVMM. RESULTS: The LV volumes determined by 13N-NH3 and 18F-FDG were 108+/-60 mL and 106+/-63 mL for ESV and 175+/-71 mL and 169+/-73 mL for EDV, respectively. The LVEFs determined by 13N-NH3 and 18F-FDG were 42%+/-13% and 41%+/-13%, respectively. The LVMMs determined by 13N-NH3 and 18F-FDG were 179+/-40 g and 183+/-43 g, respectively. All P values were not significant, as determined by paired t tests. A significant correlation was observed between 13N-NH3 imaging and 18F-FDG imaging for the calculation of ESV (r=0.97, SEE=14.1, P<0.0001), EDV (r=0.98, SEE=15.4, P<0.0001), LVEF (r=0.9, SEE=5.6, P<0.0001), and LVMM (r=0.93, SEE=15.5, P<0.0001). CONCLUSION: Model-based analysis of ECG-gated 13N-NH3 PET images is accurate in determining LV volumes, LVMM, and LVEF. Therefore, ECG-gated 13N-NH3 can be used for the simultaneous assessment of myocardial perfusion, LV geometry, and contractile function.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Imagem do Acúmulo Cardíaco de Comporta / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons / Eletrocardiografia / Ventrículos do Coração / Radioisótopos de Nitrogênio Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2005 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Imagem do Acúmulo Cardíaco de Comporta / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons / Eletrocardiografia / Ventrículos do Coração / Radioisótopos de Nitrogênio Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2005 Tipo de documento: Article