Your browser doesn't support javascript.
loading
The risk profile for obstructive sleep apnea does not affect the recurrence of atrial fibrillation.
Padeletti, Luigi; Gensini, Gian Franco; Pieragnoli, Paolo; Ravazzi, Pierantonio; Diotallevi, Paolo; Baldi, Nicola; Russo, Vitantonio; Orazi, Serafino; Occhetta, Eraldo; Padeletti, Margherita; Corbucci, Giorgio; Jelic, Sanja; Barold, S Serge.
Afiliação
  • Padeletti L; Internal Medicine and Cardiology, University of Firenze, Firenze, Italy. lpadeletti@interfree.it
Pacing Clin Electrophysiol ; 29(7): 727-32, 2006 Jul.
Article em En | MEDLINE | ID: mdl-16884508
ABSTRACT

BACKGROUND:

Obstructive sleep apnea (OSA) has been linked to increased prevalence and recurrence of atrial fibrillation (AF). We hypothesized that OSA may aggravate AF in patients with pacemakers implanted for sinus bradycardia who had documented paroxysmal AF.

METHODS:

Seventy-two patients (36 M, aged 77 +/- 6 years) completed the study. All patients received a dual-chamber pacemaker equipped with diagnostic and preventive functions for AF. OSA was diagnosed with the Berlin Questionnaire, which is validated to identify patients with OSA. Four-month continuous pacemaker recordings were collected for all patients.

RESULTS:

OSA was diagnosed in 28% of patients. Patients at high risk for OSA (HR group) and patients at low risk for OSA (LR group) were equivalent for gender, age, and body mass index. The rate of hypertension was higher in HR than in LR group (90% vs 44%, P < 0.01). The prevalence of paroxysmal AF during the study period was similar in HR and LR group (53% vs 44%, P = NS). Overall number of AF episodes per month was not significantly different between HR and LR group (7 +/- 13 vs 36 +/- 122, P = NS). Similarly, AF burden (AF%) was not significantly different between HR and LR group (0.3 +/- 0.6 vs 2.0 +/- 4.8, P = NS). Circadian distribution of AF episodes was similar in both groups.

CONCLUSION:

Long-term pacemaker recording of AF recurrence, AF burden, and its circadian distribution is similar in patients with paroxysmal AF at high risk for OSA and those at low risk for OSA.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Fibrilação Atrial / Apneia Obstrutiva do Sono Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2006 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Fibrilação Atrial / Apneia Obstrutiva do Sono Tipo de estudo: Diagnostic_studies / Etiology_studies / Prognostic_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2006 Tipo de documento: Article