Your browser doesn't support javascript.
loading
Spheromak formation by steady inductive helicity injection.
Jarboe, T R; Hamp, W T; Marklin, G J; Nelson, B A; O'neill, R G; Redd, A J; Sieck, P E; Smith, R J; Wrobel, J S.
Afiliação
  • Jarboe TR; University of Washington, Seattle, Washington 98195-2250, USA.
Phys Rev Lett ; 97(11): 115003, 2006 Sep 15.
Article em En | MEDLINE | ID: mdl-17025894
A spheromak is formed for the first time using a new steady state inductive helicity injection method. Using two inductive injectors with odd symmetry and oscillating at 5.8 kHz, a steady state spheromak with even symmetry is formed and sustained through nonlinear relaxation. A spheromak with about 13 kA of toroidal current is formed and sustained using about 3 MW of power. This is a much lower power threshold for spheromak production than required for electrode-based helicity injection. Internal magnetic probe data, including oscillations driven by the injectors, agree with the plasma being in the Taylor state. The agreement is remarkable considering the only fitting parameter is the amplitude of the spheromak component of the state.
Buscar no Google
Base de dados: MEDLINE Idioma: En Ano de publicação: 2006 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Idioma: En Ano de publicação: 2006 Tipo de documento: Article