Identification of high explosives using single-particle aerosol mass spectrometry.
Martin, Audrey N; Farquar, George R; Gard, Eric E; Frank, Matthias; Fergenson, David P.
Afiliação
  • Martin AN; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
Anal Chem ; 79(5): 1918-25, 2007 Mar 01.
Article em En | MEDLINE | ID: mdl-17249636
ABSTRACT
The application of single-particle aerosol mass spectrometry (SPAMS) to the real-time detection of micrometer-sized single particles of high explosives is described. Dual-polarity time-of-flight mass spectra from 1000 single particles each of 2,4,6-trinitrotoluene (TNT), 1,3,5-trinitro-1,3,5-triazinane (RDX), and pentaerythritol tetranitrate (PETN), as well as those of complex explosives, Composition B, Semtex 1A, and Semtex 1H, were obtained over a range of desorption/ionization laser fluences between 0.50 and 8.01 nJ/microm2. Mass spectral variability with laser fluence for each explosive is discussed. The ability of the SPAMS system to identify explosive components in a single complex explosive particle ( approximately 1 pg) without the need for consumables is demonstrated.