Your browser doesn't support javascript.
loading
Reproducibility of transient elastography in the evaluation of liver fibrosis in patients with chronic liver disease.
Fraquelli, Mirella; Rigamonti, Cristina; Casazza, Giovanni; Conte, Dario; Donato, Maria Francesca; Ronchi, Guido; Colombo, Massimo.
Afiliação
  • Fraquelli M; Second Division of Gastroenterology, Fondazione IRCCS Ospedale Maggiore Policlinico, Mangiagalli e Regina Elena, Milan, Italy. mfraquelli@yahoo.it
Gut ; 56(7): 968-73, 2007 Jul.
Article em En | MEDLINE | ID: mdl-17255218
OBJECTIVE: Transient elastography (TE) is gaining popularity as a non-invasive method for predicting liver fibrosis, but intraobserver and interobserver agreement and factors influencing TE reproducibility have not been adequately assessed. This study investigated these aspects. SETTING: Tertiary referral liver unit. PATIENTS: Over a 4-month period, 200 patients with chronic liver disease (CLD) with varying aetiology consecutively underwent TE and liver biopsy. INTERVENTIONS: TE was performed twice by two different operators either concomitantly or within 3 days of the bioptic procedure (METAVIR classification). MAIN OUTCOME MEASURES: Intraobserver and interobserver agreement were analysed using the intraclass correlation coefficient (ICC) and correlated with different patient-related and liver disease-related covariates. RESULTS: 800 TE examinations were performed, with an indeterminate result rate of 2.4%. The overall interobserver agreement ICC was 0.98 (95% CI 0.977 to 0.987). Increased body mass index (>25 kg/m(2)), steatosis, and low staging grades (fibrosis (F) stage <2) were significantly associated with reduced ICC (p<0.05). Intraobserver agreement ICC was 0.98 for both raters. Using receiver operating characteristic curves, three diagnostic TE thresholds were identified: >7.9 kPa for F>/=2, >10.3 for F>/=3 and >11.9 for F = 4. TE values assessed by the two raters fell within the same cut-off of fibrosis in 88% of the cases for F>/=2, in 92% for F>/=3 and 91% for F = 4. CONCLUSIONS: TE is a highly reproducible and user-friendly technique for assessing liver fibrosis in patients with CLD. However, because TE reproducibility is significantly reduced (p<0.05) in patients with steatosis, increased BMI and lower degrees of hepatic fibrosis, caution is warranted in the clinical use of TE as a surrogate for liver biopsy.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cirrose Hepática Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Evaluation_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2007 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cirrose Hepática Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Evaluation_studies / Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2007 Tipo de documento: Article