Your browser doesn't support javascript.
loading
Diagnostic accuracy of 18F-FDG PET in restaging patients with medullary thyroid carcinoma and elevated calcitonin levels.
Ong, Seng C; Schöder, Heiko; Patel, Snehal G; Tabangay-Lim, Ida M; Doddamane, Indukala; Gönen, Mithat; Shaha, Ashok R; Tuttle, R Michael; Shah, Jatin P; Larson, Steven M.
Afiliação
  • Ong SC; Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York 10021, USA.
J Nucl Med ; 48(4): 501-7, 2007 Apr.
Article em En | MEDLINE | ID: mdl-17401085
ABSTRACT
UNLABELLED Medullary thyroid carcinoma (MTC) is a rare endocrine tumor arising from the C-cells of the thyroid gland. Calcitonin is the principal serum tumor marker. A rising calcitonin level after total thyroidectomy for localized disease generally indicates residual, recurrent, or metastatic disease. The role of (18)F-FDG PET in MTC remains somewhat unclear. We reviewed our own experience with (18)F-FDG PET in postthyroidectomy MTC patients with elevated calcitonin.

METHODS:

From our database, we identified patients with suspected residual, recurrent, or metastatic MTC and elevated calcitonin who had been referred for (18)F-FDG PET between January 2000 and October 2005. (18)F-FDG PET findings were classified as positive or negative on the basis of visual interpretation of the scan. Standardized uptake values (SUVs) were also calculated. The (18)F-FDG PET findings were verified by histopathologic examination, when available, or other imaging studies and clinical follow-up. Any negative (18)F-FDG PET result was considered false-negative.

RESULTS:

Twenty-eight patients underwent a total of 38 (18)F-FDG PET studies. Calcitonin levels ranged from 106 to 541,000 pg/mL (median, 7,260 pg/mL). There were 23 true-positive, 1 false-positive, and 14 false-negative (18)F-FDG PET scans, yielding an overall sensitivity of 62%. There was no true-positive finding when calcitonin levels were below 509 pg/mL (n = 5). Using an arbitrary cutoff of 1,000 pg/mL, we found that the sensitivity in scans with calcitonin levels greater than 1,000 pg/mL increased to 78% (21/27; 95% confidence interval, 58%-91%). The mean SUV of all lesions with (18)F-FDG uptake was 5.3 +/- 3.2 (range, 2.0-15.9). Among the 14 patients with false-negative (18)F-FDG PET findings, 8 had concurrent anatomic imaging studies and only 2 of these had positive findings.

CONCLUSION:

(18)F-FDG PET can detect residual, recurrent, or metastatic MTC with a reasonable sensitivity of 78% when the calcitonin level is above 1,000 pg/mL but appears of limited use if the calcitonin level is below 500 pg/mL.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Calcitonina / Neoplasias da Glândula Tireoide / Carcinoma Medular / Fluordesoxiglucose F18 / Estadiamento de Neoplasias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2007 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Calcitonina / Neoplasias da Glândula Tireoide / Carcinoma Medular / Fluordesoxiglucose F18 / Estadiamento de Neoplasias Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2007 Tipo de documento: Article