Your browser doesn't support javascript.
loading
Target volume delineation for partial breast radiotherapy planning: clinical characteristics associated with low interobserver concordance.
Petersen, Ross P; Truong, Pauline T; Kader, Hosam A; Berthelet, Eric; Lee, Junella C; Hilts, Michelle L; Kader, Adam S; Beckham, Wayne A; Olivotto, Ivo A.
Afiliação
  • Petersen RP; Radiation Therapy Program, British Columbia Cancer Agency, Vancouver Island Centre, Victoria, Canada.
Int J Radiat Oncol Biol Phys ; 69(1): 41-8, 2007 Sep 01.
Article em En | MEDLINE | ID: mdl-17707265
ABSTRACT

PURPOSE:

To examine variability in target volume delineation for partial breast radiotherapy planning and evaluate characteristics associated with low interobserver concordance. METHODS AND MATERIALS Thirty patients who underwent planning CT for adjuvant breast radiotherapy formed the study cohort. Using a standardized scale to score seroma clarity and consensus contouring guidelines, three radiation oncologists independently graded seroma clarity and delineated seroma volumes for each case. Seroma geometric center coordinates, maximum diameters in three axes, and volumes were recorded. Conformity index (CI), the ratio of overlapping volume and encompassing delineated volume, was calculated for each case. Cases with CI RESULTS: The median time from surgery to CT was 42.5 days. For geometric center coordinates, variations from the mean were 0.5-1.1 mm and standard deviations (SDs) were 0.5-1.8 mm. For maximum seroma dimensions, variations from the mean and SDs were predominantly <5 mm, with the largest SDs observed in the medial-lateral axis. The mean CI was 0.61 (range, 0.27-0.84). Five cases had CI seroma clarity (p < 0.001) and seroma volume (p < 0.002). Features associated with reduced concordance included tissue stranding from the surgical cavity, proximity to muscle, dense breast parenchyma, and benign calcifications that may be mistaken for surgical clips.

CONCLUSION:

Variability in seroma contouring occurred in three dimensions, with the largest variations in the medial-lateral axis. Awareness of clinical features associated with reduced concordance may be applied toward training staff and refining contouring guidelines for partial breast radiotherapy trials.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Neoplasias da Mama / Guias de Prática Clínica como Assunto / Radioterapia (Especialidade) / Seroma Tipo de estudo: Diagnostic_studies / Evaluation_studies / Guideline / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Middle aged Idioma: En Ano de publicação: 2007 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Neoplasias da Mama / Guias de Prática Clínica como Assunto / Radioterapia (Especialidade) / Seroma Tipo de estudo: Diagnostic_studies / Evaluation_studies / Guideline / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Middle aged Idioma: En Ano de publicação: 2007 Tipo de documento: Article