Radiation exposure to surgical staff during F-18-FDG-guided cancer surgery.
Andersen, P A; Chakera, A H; Klausen, T L; Binderup, T; Grossjohann, H S; Friis, E; Palnaes Hansen, C; Schmidt, G; Kjaer, A; Hesse, B.
Afiliação
  • Andersen PA; Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital, 3992 Rigshospitalet, Copenhagen, Denmark. paa@pet.rh.dk
Eur J Nucl Med Mol Imaging ; 35(3): 624-9, 2008 Mar.
Article em En | MEDLINE | ID: mdl-17955240
ABSTRACT

PURPOSE:

High-energy gamma probes have recently become commercially available, developed for (18)F-FDG probe-guided surgery. The radiation received by the staff in the operating room might limit the use of it, but has never been determined. We therefore wanted to measure the absorbed staff doses at operations where patients had received a preoperative injection of (18)F-FDG.

METHODS:

Thirty-four patients with different cancers (breast cancer, melanoma, gastrointestinal cancers, respectively) were operated. At every operation the surgeon was monitored with a TLD tablet on his finger of the operating hand and a TLD tablet on the abdomen. The surgeon and anaesthesiologist were also monitored using electronic dosimeters placed in the trousers lining at 25 operations.

RESULTS:

The dose rate to the surgeon's abdominal wall varied between 7.5-13.2 microSv/h, depending on tumour location. The doses to the anaesthesiologists and the finger doses to the surgeon were much lower. About 350-400 MBq, i.e. ca. eight times higher activities than those used in the present study are supposed to be necessary for guiding surgery. It can be calculated from the body doses measured that a surgeon can perform between 150-260 h of surgery without exceeding permissible limits for professional workers.

CONCLUSIONS:

The radiation load to the operating staff will generally be so small that it does not present any limitation for FDG-guided surgery. However, it is recommended to monitor the surgical staff considering that the surgeon may be exposed to other radiation sources, and since the staff often includes women of child-bearing age.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Centro Cirúrgico Hospitalar / Monitoramento de Radiação / Exposição Ocupacional / Pessoal de Saúde / Fluordesoxiglucose F18 / Cirurgia Assistida por Computador Limite: Adult / Aged / Female / Humans / Male / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2008 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Centro Cirúrgico Hospitalar / Monitoramento de Radiação / Exposição Ocupacional / Pessoal de Saúde / Fluordesoxiglucose F18 / Cirurgia Assistida por Computador Limite: Adult / Aged / Female / Humans / Male / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2008 Tipo de documento: Article