Your browser doesn't support javascript.
loading
On the benefits of acquiring peptide fragment ions at high measured mass accuracy.
Scherl, Alexander; Shaffer, Scott A; Taylor, Gregory K; Hernandez, Patricia; Appel, Ron D; Binz, Pierre-Alain; Goodlett, David R.
Afiliação
  • Scherl A; Department of Medicinal Chemistry, University of Washington, Seattle, Washington, USA.
J Am Soc Mass Spectrom ; 19(6): 891-901, 2008 Jun.
Article em En | MEDLINE | ID: mdl-18417358
ABSTRACT
The advantages and disadvantages of acquiring tandem mass spectra by collision-induced dissociation (CID) of peptides in linear ion trap Fourier-transform hybrid instruments are described. These instruments offer the possibility to transfer fragment ions from the linear ion trap to the FT-based analyzer for analysis with both high resolution and high mass accuracy. In addition, performing CID during the transfer of ions from the linear ion trap (LTQ) to the FT analyzer is also possible in instruments containing an additional collision cell (i.e., the "C-trap" in the LTQ-Orbitrap), resulting in tandem mass spectra over the full m/z range and not limited by the ejection q value of the LTQ. Our results show that these scan modes have lower duty cycles than tandem mass spectra acquired in the LTQ with nominal mass resolution, and typically result in fewer peptide identifications during data-dependent analysis of complex samples. However, the higher measured mass accuracy and resolution provides more specificity and hence provides a lower false positive ratio for the same number of true positives during database search of peptide tandem mass spectra. In addition, the search for modified and unexpected peptides is greatly facilitated with this data acquisition mode. It is therefore concluded that acquisition of tandem mass spectral data with high measured mass accuracy and resolution is a competitive alternative to "classical" data acquisition strategies, especially in situations of complex searches from large databases, searches for modified peptides, or for peptides resulting from unspecific cleavages.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Mapeamento de Peptídeos / Espectroscopia de Infravermelho com Transformada de Fourier / Espectrometria de Massas por Ionização por Electrospray Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Ano de publicação: 2008 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Mapeamento de Peptídeos / Espectroscopia de Infravermelho com Transformada de Fourier / Espectrometria de Massas por Ionização por Electrospray Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Ano de publicação: 2008 Tipo de documento: Article