The influence of the alloy of megaprostheses on infection rate.
J Arthroplasty
; 23(6): 916-20, 2008 Sep.
Article
em En
| MEDLINE
| ID: mdl-18534530
We retrospectively reviewed 197 patients who underwent reconstruction with a megaprosthesis of the lower extremity. A cobalt-chrome alloy system was used in 77 patients and a titanium alloy system in 120 patients. The overall infection rate was 20.8% (n = 41). Separated into the 2 prosthesis systems used, an infection rate of 31.2% was found in the patients with a cobalt-chrome-alloy prosthesis and 14.2% in the titanium alloy group of patients (P < .01). Early infection occurred in 5.1% (n = 10) and late infection in 15.7% (n = 31). Selecting 2 identical subgroups for further analysis, the cobalt-chrome alloy prostheses were associated with a significantly higher infection rate, with 5 infections of 26 megaprostheses vs 1 infection of 36 titanium megaprostheses (P < .05).
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Membros Artificiais
/
Titânio
/
Infecções Bacterianas
/
Ligas de Cromo
/
Ligas
Tipo de estudo:
Etiology_studies
/
Incidence_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Adolescent
/
Adult
/
Aged
/
Aged80
/
Child
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
2008
Tipo de documento:
Article