Death during laparoscopy: can 1 gas push out another? Danger of argon electrocoagulation.
Surg Laparosc Endosc Percutan Tech
; 18(4): 395-7, 2008 Aug.
Article
em En
| MEDLINE
| ID: mdl-18716541
ABSTRACT
We report the death of a young man during a laparoscopic partial splenectomy performed with an argon plasma coagulator to remove a benign cyst. The report analyzes the very particular mechanism of a gas embolism, which caused death here. This analysis leads us to recommend a close attention on the use of argon coagulators during laparoscopy. The aim of this article is to draw surgeons' attention to the conclusions of a court-ordered expert assessment intended to elucidate the mechanisms responsible for the death of a 20-year-old man during a laparoscopic partial splenectomy performed with an argon plasma coagulator to remove a benign cyst.