ABSTRACT
This study aims to determine inter- and intra-observer variation in MRI measurements of relative bowel wall signal intensity (SI) in Crohn's disease. Twenty-one small bowel MRI examinations (11 male, mean age 40), including T1-weighted acquisitions acquired 30 to 120s post-gadolinium, were analysed. Maximal bowel wall SI (most avid, conspicuous contrast enhancement) in designated diseased segments was measured by two radiologists and two trainees using self-positioned "free" regions of interest (ROIs) followed by "fixed" ROIs chosen by one radiologist, and this procedure was repeated 1 month later. Relative enhancement (post-contrast SI minus pre-contrast SI/pre-contrast SI) was calculated. Data were analysed using Bland-Altman limits of agreement and intra-class correlation. Inter-observer agreement for relative enhancement was poor (spanning over 120%) using a free ROI-95% limits of agreement -0.69, 0.70 and -0.47, 0.74 for radiologists and trainees, respectively, only marginally improved by use of a fixed ROI -0.60, 0.67 and -0.59, 0.49. Intra-class correlation ranged from 0.46 to 0.72. Intra-observer agreement was slightly better and optimised using a fixed ROI-95% limits of agreement -0.52, 0.50 and -0.34, 0.28 for radiologists and trainees, respectively. Intra-class correlation ranged from 0.49 to 0.86. Relative bowel wall signal intensity measurements demonstrate wide limits of observer agreement, unrelated to reader experience but improved using fixed ROIs.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Doença de Crohn / Gadolínio DTPA / Intestino Delgado Tipo de estudo: Diagnostic_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2009 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Algoritmos / Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Doença de Crohn / Gadolínio DTPA / Intestino Delgado Tipo de estudo: Diagnostic_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2009 Tipo de documento: Article