Your browser doesn't support javascript.
loading
Prediction of hypertension improvement after stenting of renal artery stenosis: comparative accuracy of translesional pressure gradients, intravascular ultrasound, and angiography.
Leesar, Massoud A; Varma, Jai; Shapira, Adam; Fahsah, Ibrahim; Raza, Seyed T; Elghoul, Ziad; Leonard, Anthony C; Meganathan, Karthikeyan; Ikram, Sohail.
Afiliação
  • Leesar MA; Division of Cardiology, University of Louisville, Louisville, Kentucky, USA. leesarma@uc.edu
J Am Coll Cardiol ; 53(25): 2363-71, 2009 Jun 23.
Article em En | MEDLINE | ID: mdl-19539148
ABSTRACT

OBJECTIVES:

We investigated the comparative accuracy of renal translesional pressure gradients (TPG), intravascular ultrasound (IVUS), and angiographic parameters in predicting hypertension improvement after stenting of renal artery stenosis (RAS).

BACKGROUND:

The degree of RAS that justifies stenting is unknown.

METHODS:

In 62 patients with RAS, TPG (resting and hyperemic systolic gradient [HSG], fractional flow reserve, and mean gradient) were measured by a pressure guidewire; IVUS and angiographic parameters (minimum lumen area and diameter, area stenosis, and diameter stenosis) were measured by quantitative analyses.

RESULTS:

The HSG had a larger area under the curve than most other parameters and an HSG >or=21 mm Hg had the highest sensitivity, specificity, and accuracy (82%, 84%, and 84%, respectively) in predicting hypertension improvement after stenting of RAS. The average IVUS area stenosis was markedly greater in RAS with an HSG >or=21 mm Hg versus <21 mm Hg (78% vs. 38%, respectively; p < 0.001). After stenting, hypertension improved in 84% of patients with an HSG >or=21 mm Hg (n = 36) versus 36% of patients with an HSG <21 mm Hg (n = 26) at 12 months, p < 0.01; the number of antihypertensive medications was significantly lower in patients with an HSG >or=21 mm Hg versus <21 mm Hg (2.30 +/- 0.90 vs. 3.40 +/- 0.50, respectively; p < 0.01). By multivariable analysis, HSG was the only independent predictor of hypertension improvement (odds ratio 1.39; 95% confidence interval 1.05 to 1.65; p = 0.013).

CONCLUSIONS:

An HSG >or=21 mm Hg provided the highest accuracy in predicting hypertension improvement after stenting of RAS, suggesting that an HSG >or=21 mm Hg is indicative of significant RAS.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Obstrução da Artéria Renal / Pressão Sanguínea / Hipertensão Renovascular Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Humans / Middle aged Idioma: En Ano de publicação: 2009 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Obstrução da Artéria Renal / Pressão Sanguínea / Hipertensão Renovascular Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Humans / Middle aged Idioma: En Ano de publicação: 2009 Tipo de documento: Article