Your browser doesn't support javascript.
loading
Confocal laser endomicroscopy in experimental pigs. Methods of ex vivo imaging.
Kopácová, M; Bures, J; Osterreicher, J; Kvetina, J; Pejchal, J; Tachecí, I; Kunes, M; Spelda, S; Rejchrt, S.
Afiliação
  • Kopácová M; Second Department of Internal Medicine, Charles University in Praha, Faculty of Medicine at Hradec Králové, University Teaching Hospital, Hradec Králové, Czech Republic. kopacmar@fnhk.cz
Cas Lek Cesk ; 148(6): 249-53, 2009.
Article em En | MEDLINE | ID: mdl-19642306
ABSTRACT

BACKGROUND:

Confocal laser scanning endomicroscopy (CLSE) enables online in vivo cellular surface and subsurface imaging of normal and pathological tissue at high resolution and magnification. The aim of this study was to work out a method of ex vivo in vitro CLSE in experimental pigs and to compare CLSE images with those of "classic" histology. MATERIAL AND

METHODS:

Five mature female pigs entered the study. CLSE on an ex vivo in vitro basis was started 10 minutes after pharmacological euthanasia and carried out for 30 minutes. Fluorescein was administrated i.v. as a fluorescence substance.

RESULTS:

CLSE was successful in all tissue samples of all animals (the oesophagus, stomach, small intestine, large bowel). We have succeeded to obtain high quality images within the first 30 minutes that means 40 minutes after the euthanasia of experimental animals. CLSE images corresponded well with those of haematoxylin-eosin staining.

CONCLUSIONS:

CLSE on an ex vivo in vitro basis in experimental pigs is feasible.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Microscopia Confocal Limite: Animals Idioma: En Ano de publicação: 2009 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Microscopia Confocal Limite: Animals Idioma: En Ano de publicação: 2009 Tipo de documento: Article