A comparison of volatile and non volatile agents for cardioprotection during on-pump coronary surgery.
Anaesthesia
; 64(9): 953-60, 2009 Sep.
Article
em En
| MEDLINE
| ID: mdl-19686479
A randomised study of 414 patients undergoing coronary artery surgery with cardiopulmonary bypass was conducted to compare the effects of a volatile anaesthetic regimen with either deesflurane or sevoflurane, and a total intravenous anaesthesia (TIVA) regimen on postoperative troponin T release. The primary outcome variable was postoperative troponin T release, secondary outcome variables were hospital length of stay and 1-year mortality. Maximal postoperative troponin T values did not differ between groups (TIVA: 0.30 [0.00-4.79] ng x ml(-1) (median [range]), sevoflurane: 0.33 [0.02-3.68] ng x ml(-1), and desflurane: 0.39 [0.08-3.74] ng x ml(-1)). The independent predictors of hospital length of stay were the EuroSCORE (p < 0.001), female gender (p = 0.042) and the group assignment (p < 0.001). The one-year mortality was 12.3% in the TIVA group, 3.3% in the sevoflurane group, and 6.7% in the desflurane group. The EuroSCORE (p = 0.003) was the only significant independent predictor of 1-year mortality.
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Cardiotônicos
/
Traumatismo por Reperfusão Miocárdica
/
Ponte de Artéria Coronária
/
Anestésicos Intravenosos
/
Anestésicos Inalatórios
Tipo de estudo:
Clinical_trials
/
Etiology_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
2009
Tipo de documento:
Article