Your browser doesn't support javascript.
loading
Individualized dosimetry in patients undergoing therapy with (177)Lu-DOTA-D-Phe (1)-Tyr (3)-octreotate.
Sandström, Mattias; Garske, Ulrike; Granberg, Dan; Sundin, Anders; Lundqvist, Hans.
Afiliação
  • Sandström M; Department of Oncology, Radiology and Clinical Immunology, Uppsala University Hospital, 751 85, Uppsala, Sweden. mattias.sandstrom@akademiska.se
Eur J Nucl Med Mol Imaging ; 37(2): 212-25, 2010 Feb.
Article em En | MEDLINE | ID: mdl-19727718
ABSTRACT

PURPOSE:

In recent years, targeted radionuclide therapy with [(177)Lu-DOTA(0), Tyr(3)]octreotate for neuroendocrine tumours has yielded promising results. This therapy may be further improved by using individualized dosimetry allowing optimization of the absorbed dose to the tumours and the normal organs. The aim of this study was to investigate the feasibility and reliability of individualized dosimetry based on SPECT in comparison to conventional planar imaging.

METHODS:

Attenuation-corrected SPECT data were analysed both by using organ-based volumes of interest (VOIs) to obtain the total radioactivity in the organ, and by using small VOIs to measure the tissue radioactivity concentration. During the first treatment session in 24 patients, imaging was performed 1, 24, 96 and 168 h after [(177)Lu-DOTA(0), Tyr(3)]octreotate infusion. Absorbed doses in non tumour-affected kidney, liver and spleen were calculated and compared for all three methods (planar imaging, SPECT organ VOIs, SPECT small VOIs).

RESULTS:

Planar and SPECT dosimetry were comparable in areas free of tumours, but due to overlap the planar dosimetry highly overestimated the absorbed dose in organs with tumours. Furthermore, SPECT dosimetry based on small VOIs proved to be more reliable than whole-organ dosimetry.

CONCLUSION:

We conclude that SPECT dosimetry based on small VOIs is feasible and more accurate than conventional planar dosimetry, and thus may contribute towards optimising targeted radionuclide therapy.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Interpretação de Imagem Assistida por Computador / Octreotida / Tomografia Computadorizada de Emissão de Fóton Único / Tumores Neuroendócrinos Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Male Idioma: En Ano de publicação: 2010 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Interpretação de Imagem Assistida por Computador / Octreotida / Tomografia Computadorizada de Emissão de Fóton Único / Tumores Neuroendócrinos Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Male Idioma: En Ano de publicação: 2010 Tipo de documento: Article