Your browser doesn't support javascript.
loading
Comparison of the Visian ICL and Verisyse phakic intraocular lenses for myopia from 6.00 to 20.00 diopters.
Boxer Wachler, Brian S; Scruggs, Ryan T; Yuen, Leonard H; Jalali, Shahrokh.
Afiliação
  • Boxer Wachler BS; Boxer Wachler Vision Institute, Beverly Hills, CA, USA. bbw@boxerwachler.com
J Refract Surg ; 25(9): 765-70, 2009 Sep.
Article em En | MEDLINE | ID: mdl-19772261
ABSTRACT

PURPOSE:

To compare visual and refractive outcomes between the Visian Implantable Collamer Lens (ICL) and Verisyse phakic intraocular lens.

METHODS:

Comparative interventional case series for myopia between 6.00 and 20.00 diopters (D). Thirty consecutive eyes of 16 patients had a Visian ICL implanted and 31 consecutive eyes of 19 patients had the Verisyse lens implanted. Outcomes measured at 3 months postoperatively included uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and refractive predictability as well as adverse events. Preoperatively, the groups were no different in regard to age (P=.72) and spherical equivalent refraction (P=.38).

RESULTS:

Postoperative UCVA of 20/20 or better and 20/25 or better in the Visian ICL group was 67% and 96%, respectively, compared to 63% and 79%, respectively, in the Verisyse lens group (P=.10). Binocular UCVA of 20/20 or better and 20/25 or better in the Visian ICL group was 92% and 100%, respectively, and in the Verisyse group, 70% and 80%, respectively (P=.007). One and two lines gain of postoperative BSCVA in the Visian ICL group was 40% and 10%, respectively, which was statistically significantly better than the Verisyse group of 16% and 6%, respectively (P=.025). Postoperative deviation from target refraction was 0.038+/-0.39 D in the Visian ICL group and -0.38+/-0.89 D in the Verisyse lens group (P=.018).

CONCLUSIONS:

Monocular UCVA was similar for both groups, whereas binocular UCVA was better in the Visian ICL group. The Visian ICL group had more accurate refractive outcomes than the Verisyse lens group.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Implante de Lente Intraocular / Lentes Intraoculares Fácicas / Miopia Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2009 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Implante de Lente Intraocular / Lentes Intraoculares Fácicas / Miopia Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2009 Tipo de documento: Article