Early Doppler-echocardiography evaluation of 597 prosthetic aortic valves.
Minardi, Giovanni; Pino, Paolo G; Manzara, Carla C; Pulignano, Giovanni; Viceconte, Giuseppe N; Stefanini, Giulio G; Gaudio, Carlo; Musumeci, Francesco.
Afiliação
  • Minardi G; Department of Cardiovascular Science, S. Camillo-Forlanini Hospital, Rome, Italy. giovanni.minardi@libero.it
J Cardiovasc Med (Hagerstown) ; 11(4): 229-33, 2010 Apr.
Article em En | MEDLINE | ID: mdl-20090552
OBJECTIVES: This study was designed to describe the Doppler-echocardiography normal values in the early postoperative phase for Carpentier-Edwards Perimount Aortic Heart Valve bioprosthesis (CEP), St. Jude Medical (SJM) or Medical Regent (SJMR) Mechanical Heart Valves, evaluated by a single experienced echo-laboratory. METHODS: Five hundred and ninety-seven consecutive patients in our hospital, who had had a CEP, a SJM or SJMR-17 mm implanted due to aortic stenosis, underwent a control Doppler-echocardiography evaluation 4-7 days after surgery. Hemodynamic performance of SJM, SJMR and CEP were accurately described, evaluating flow-dependent (trans-prosthetic velocities and gradients) and flow-independent (effective orifice area, indexed effective orifice area and Doppler velocity index) Doppler-echocardiography parameters. RESULTS: Of the 597 patients 50.6% were women (n = 302). Mean age was 66.3 +/- 11.7 years. Mean body surface area (BSA) was 1.76 +/- 0.22 m. Mean ejection fraction was 55.3 +/- 10.3%. Two hundred and sixty CEPs and 337 St. Jude mechanical valves (301 SJM and 36 SJMR size-17) were implanted. Comparing size-by-size SJM to CEP, the former were basically less flow obstructive. CONCLUSION: Our data confirm the wide range of variability, pointing out the need to perform routinely an accurate baseline Doppler-echocardiography evaluation of the hemodynamic profile of prosthetic aortic valves, including flow-dependent and independent parameters, to allow an adequate interpretation at follow-up.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Bioprótese / Próteses Valvulares Cardíacas / Ecocardiografia Doppler Tipo de estudo: Evaluation_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2010 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Valva Aórtica / Bioprótese / Próteses Valvulares Cardíacas / Ecocardiografia Doppler Tipo de estudo: Evaluation_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2010 Tipo de documento: Article