Your browser doesn't support javascript.
loading
Comparison of gadoxetic acid-enhanced MR imaging versus four-phase multi-detector row computed tomography in assessing tumor regression after radiofrequency ablation in subjects with hepatocellular carcinomas.
Yoon, Jung-Hee; Lee, Eun-Joo; Cha, Seong-Sook; Han, Sang-Suk; Choi, Suk-Jin; Juhn, Jae-Ryang; Kim, Myung-Hee; Lee, Yeon-Jae; Park, Seong-Jae.
Afiliação
  • Yoon JH; Department of Radiology, Busan Paik Hospital, Inje University College of Medicine, Busan, Korea. minkimom@yahoo.co.kr
J Vasc Interv Radiol ; 21(3): 348-56, 2010 Mar.
Article em En | MEDLINE | ID: mdl-20116285
ABSTRACT

PURPOSE:

To assess the diagnostic value of gadoxetic acid-enhanced magnetic resonance (MR) imaging in follow-up of patients with hepatocellular carcinomas (HCCs) who were treated with radiofrequency (RF) ablation and to compare it with that of four-phase multi-detector row computed tomography (CT). MATERIALS AND

METHODS:

From July 2007 to May 2008, 36 patients (43 HCCs) were enrolled who were treated with RF ablation (tumor size, 20-47 mm; mean, 24.5 mm) and underwent gadoxetic acid-enhanced MR imaging and four-phase (precontrast, arterial, portal venous, and equilibrium) multidetector CT for follow-up. Two radiologists independently reviewed these images, and conspicuity of tumor margins and detection of residual or recurrent tumor were assessed on a five-point scale with receiver operating characteristic (ROC) curve analysis. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were evaluated.

RESULTS:

The mean conspicuity value of tumor margins was significantly higher on MR imaging than on multidetector CT (P < .001). The degree of differentiation between residual/recurrent tumor and hyperemia was significantly greater on MR imaging (P < .001). The mean area under the ROC curve was significantly higher with MR imaging (P = .015), as were sensitivity, specificity, PPV, NPV, and accuracy of detection rate (mean, 100%, 96.2%, 82.4%, 100%, and 96.7%, respectively, vs 41.7%, 56.8%, 13.5%, 85.7%, and 54.7% for multidetector CT). The interobserver agreement rate for MR imaging was higher (0.919) than for multidetector CT (0.672; P < .05).

CONCLUSIONS:

Diagnostic accuracy, conspicuity of tumor margins, and detection rate of residual or recurrent tumor were found to be better with gadoxetic acid-enhanced MR imaging than with four-phase multidetector CT.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X / Carcinoma Hepatocelular / Gadolínio DTPA / Neoplasias Hepáticas Tipo de estudo: Clinical_trials / Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2010 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X / Carcinoma Hepatocelular / Gadolínio DTPA / Neoplasias Hepáticas Tipo de estudo: Clinical_trials / Diagnostic_studies / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2010 Tipo de documento: Article