Your browser doesn't support javascript.
loading
Computer-assisted analysis of peripheral zone prostate lesions using T2-weighted and dynamic contrast enhanced T1-weighted MRI.
Vos, Pieter C; Hambrock, Thomas; Barenstz, Jelle O; Huisman, Henkjan J.
Afiliação
  • Vos PC; Department of Radiology, Radboud University Medical Centre, Nijmegen, 6525GA, The Netherlands. p.vos@rad.umcn.nl
Phys Med Biol ; 55(6): 1719-34, 2010 Mar 21.
Article em En | MEDLINE | ID: mdl-20197602
ABSTRACT
In this study, computer-assisted analysis of prostate lesions was researched by combining information from two different magnetic resonance (MR) modalities T2-weighted (T2-w) and dynamic contrast-enhanced (DCE) T1-w images. Two issues arise when incorporating T2-w images in a computer-aided diagnosis (CADx) system T2-w values are position as well as sequence dependent and images can be misaligned due to patient movement during the acquisition. A method was developed that computes T2 estimates from a T2-w and proton density value and a known sequence model. A mutual information registration strategy was implemented to correct for patient movement. Global motion is modelled by an affine transformation, while local motion is described by a volume preserving non-rigid deformation based on B-splines. The additional value to the discriminating performance of a DCE T1-w-based CADx system was evaluated using bootstrapped ROC analysis. T2 estimates were successfully computed in 29 patients. T2 values were extracted and added to the CADx system from 39 malignant, 19 benign and 29 normal annotated regions. T2 values alone achieved a diagnostic accuracy of 0.85 (0.77-0.92) and showed a significantly improved discriminating performance of 0.89 (0.81-0.95), when combined with DCE T1-w features. In conclusion, the study demonstrated a simple T2 estimation method that has a diagnostic performance such that it complements a DCE T1-w-based CADx system in discriminating malignant lesions from normal and benign regions. Additionally, the T2 estimate is beneficial to visual inspection due to the removed coil profile and fixed window and level settings.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Próstata / Neoplasias da Próstata / Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Meios de Contraste Tipo de estudo: Prognostic_studies Limite: Aged / Humans / Male / Middle aged Idioma: En Ano de publicação: 2010 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Próstata / Neoplasias da Próstata / Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Meios de Contraste Tipo de estudo: Prognostic_studies Limite: Aged / Humans / Male / Middle aged Idioma: En Ano de publicação: 2010 Tipo de documento: Article