Your browser doesn't support javascript.
loading
Role of three-dimensional echocardiography in breast cancer: comparison with two-dimensional echocardiography, multiple-gated acquisition scans, and cardiac magnetic resonance imaging.
Walker, Jonathan; Bhullar, Navdeep; Fallah-Rad, Nazanin; Lytwyn, Matthew; Golian, Mehrdad; Fang, Tielan; Summers, Arthur R; Singal, Pawan K; Barac, Ivan; Kirkpatrick, Iain D; Jassal, Davinder S.
Afiliação
  • Walker J; Institute of Cardiovascular Sciences, Cardiology Division, St Boniface General Hospital, University of Manitoba, Canada.
J Clin Oncol ; 28(21): 3429-36, 2010 Jul 20.
Article em En | MEDLINE | ID: mdl-20530277
ABSTRACT

PURPOSE:

In patients with breast cancer, the administration of doxorubicin and trastuzumab is associated with an increased risk of cardiotoxicity. Although multiple-gated acquisition (MUGA) scans and two-dimensional transthoracic echocardiography (TTE) are conventional methods for baseline and serial assessment of left ventricular ejection fraction (LVEF) in these patients, little is known about the use of real-time three-dimensional TTE (RT3D TTE) in this clinical setting. The aim of this study was to assess the accuracy of MUGA, 2D TTE, and RT3D TTE for determining LVEF in comparison to cardiac magnetic resonance imaging (CMR).

METHODS:

Between 2007 and 2009 inclusive, 50 female patients with human epidermal growth factor receptor 2-positive breast cancer received adjuvant trastuzumab after doxorubicin. Serial MUGA, 2D TTE, RT3D TTE, and CMR were performed at baseline, 6, and 12 months after the initiation of trastuzumab.

RESULTS:

A comparison of left ventricular end diastolic volume (LVEDV) demonstrated a modest correlation between 2D TTE and CMR (r = 0.64 at baseline; r = 0.69 at 12 months, respectively). A comparison of LVEDV between RT3D TTE and CMR demonstrated a stronger correlation (r = 0.87 at baseline; r = 0.95 at 12 months, respectively). Although 2D TTE demonstrated a weak correlation with CMR for LVEF assessment (r = 0.31 at baseline, r = 0.42 at 12 months, respectively), both RT3D TTE and MUGA showed a strong correlation when compared with CMR (r = 0.91 at baseline; r = 0.90 at 12 months, respectively).

CONCLUSION:

As compared with conventional MUGA, RT3D TTE is a feasible, accurate, and reproducible alternate imaging modality for the serial monitoring of LVEF in patients with breast cancer.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Imageamento por Ressonância Magnética / Ecocardiografia / Ecocardiografia Tridimensional Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Ano de publicação: 2010 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Imageamento por Ressonância Magnética / Ecocardiografia / Ecocardiografia Tridimensional Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Ano de publicação: 2010 Tipo de documento: Article