Seasonal evaluation of outdoor/indoor air quality in primary schools in Lisbon.
J Environ Monit
; 13(3): 657-67, 2011 Mar.
Article
em En
| MEDLINE
| ID: mdl-21274462
The aim of this study was to evaluate the indoor (I) and outdoor (O) levels of NO2, speciated volatile organic compounds (VOCs) and carbonyls at fourteen primary schools in Lisbon (Portugal) during spring, autumn and winter. Three of these schools were also selected to be monitored for comfort parameters, such as temperature and relative humidity, carbon dioxide (CO2), carbon monoxide (CO), total VOCs, and both bacterial and fungal colony-forming units per cubic metre. The concentration of CO2 and bioaerosols greatly exceeded the acceptable maximum values of 1800 mg m⻳ and 500 CFU m⻳, respectively, in all seasons. Most of the assessed VOCs and carbonyls occurred at I/O ratios above unity in all seasons, thus showing the importance of indoor sources and building conditions in indoor air quality. However, it has been observed that higher indoor VOC concentrations occurred more often in the colder months, while carbonyl concentrations were higher in the warm months. In general, the I/O NO2 ratios ranged between 0.35 and 1, never exceeding the unity. Some actions are suggested to improve the indoor air quality in Lisbon primary schools.
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Poluição do Ar em Ambientes Fechados
/
Microbiologia do Ar
/
Poluentes Atmosféricos
/
Compostos Orgânicos Voláteis
Limite:
Animals
/
Humans
País como assunto:
Europa
Idioma:
En
Ano de publicação:
2011
Tipo de documento:
Article