Your browser doesn't support javascript.
loading
Initial clinical test of a breast-PET scanner.
Raylman, Raymond R; Abraham, Jame; Hazard, Hannah; Koren, Courtney; Filburn, Shannon; Schreiman, Judith S; Kurian, Sobha; Majewski, Stan; Marano, Gary D.
Afiliação
  • Raylman RR; Department of Radiology Hematology/Oncology, Mary Babb Randolph Cancer Center, West Virginia University, Morgantown, WV, USA. rraylman@wvu.edu
J Med Imaging Radiat Oncol ; 55(1): 58-64, 2011 Feb.
Article em En | MEDLINE | ID: mdl-21382190
INTRODUCTION: The goal of this initial clinical study was to test a new positron emission/tomography imager and biopsy system (PEM/PET) in a small group of selected subjects to assess its clinical imaging capabilities. Specifically, the main task of this study is to determine whether the new system can successfully be used to produce images of known breast cancer and compare them to those acquired by standard techniques. METHODS: The PEM/PET system consists of two pairs of rotating radiation detectors located beneath a patient table. The scanner has a spatial resolution of ∼2 mm in all three dimensions. The subjects consisted of five patients diagnosed with locally advanced breast cancer ranging in age from 40 to 55 years old scheduled for pre-treatment, conventional whole body PET imaging with F-18 Fluorodeoxyglucose (FDG). The primary lesions were at least 2 cm in diameter. RESULTS: The images from the PEM/PET system demonstrated that this system is capable of identifying some lesions not visible in standard mammograms. Furthermore, while the relatively large lesions imaged in this study where all visualised by a standard whole body PET/CT scanner, some of the morphology of the tumours (ductal infiltration, for example) was better defined with the PEM/PET system. Significantly, these images were obtained immediately following a standard whole body PET scan. CONCLUSIONS: The initial testing of the new PEM/PET system demonstrated that the new system is capable of producing good quality breast-PET images compared standard methods.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Reconhecimento Automatizado de Padrão / Interpretação de Imagem Assistida por Computador / Armazenamento e Recuperação da Informação / Técnica de Subtração / Imageamento Tridimensional / Tomografia por Emissão de Pósitrons Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Middle aged Idioma: En Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Reconhecimento Automatizado de Padrão / Interpretação de Imagem Assistida por Computador / Armazenamento e Recuperação da Informação / Técnica de Subtração / Imageamento Tridimensional / Tomografia por Emissão de Pósitrons Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Middle aged Idioma: En Ano de publicação: 2011 Tipo de documento: Article