Your browser doesn't support javascript.
loading
Semi-automatic determination of detailed vertebral shape from lumbar radiographs using active appearance models.
Roberts, M G; Oh, T; Pacheco, E M B; Mohankumar, R; Cootes, T F; Adams, J E.
Afiliação
  • Roberts MG; Imaging Science and Biomedical Engineering, University of Manchester, Stopford Building, Oxford Road, Manchester M13 9PT, UK. martin.roberts@manchester.ac.uk
Osteoporos Int ; 23(2): 655-64, 2012 Feb.
Article em En | MEDLINE | ID: mdl-21431411
SUMMARY: The vertebral endplates in lumbar radiographs were located by a semi-automatic annotation method using statistical shape models. INTRODUCTION: Vertebral fractures are common osteoporotic fractures, but current quantitative detection methods (morphometry) lack specificity. We have previously developed more specific quantitative classifiers of vertebral fracture using shape and appearance models. This method has only been applied to DXA vertebral fracture assessment (VFA) images and not to spinal radiographs. The classifiers require a detailed annotation of the outline of the vertebral endplate, so we investigated the application of similar semi-automated annotation methods to lumbar radiographs as the initial step in the generalisation of the statistical classifiers used in VFA images. METHODS: The vertebral body outlines in a training set of 670 lumbar radiographs were manually annotated by expert radiologists. This training set was used to build statistical models of vertebral shape and appearance using triplets of vertebrae. In order to segment vertebrae, the models were refitted using a sequence of active appearance models of vertebral triplets, using a miss-40-out train/test cross-validation experiment. The accuracy was evaluated against the manual annotation and analysed by fracture grade. RESULTS: Good accuracy was obtained for normal vertebrae (0.82 mm) and fracture grades 1 and 2 (1.19 mm), but the localisation accuracy deteriorated for grade 3 fractures to 2.12 mm. CONCLUSION: Vertebral body shape annotation can be substantially automated on lumbar radiographs. However, an occasional manual correction may be required, typically with either severe fractures, or when there is a high degree of projectional tilting or scoliosis. The located detailed shapes may enable the development of more powerful quantitative classifiers of osteoporotic vertebral fracture.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Radiográfica Assistida por Computador / Fraturas da Coluna Vertebral / Fraturas por Osteoporose / Vértebras Lombares Tipo de estudo: Evaluation_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Radiográfica Assistida por Computador / Fraturas da Coluna Vertebral / Fraturas por Osteoporose / Vértebras Lombares Tipo de estudo: Evaluation_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2012 Tipo de documento: Article