Your browser doesn't support javascript.
loading
Reproducibility of neutron activated Sm-153 oral dose formulations intended for human administration.
Yeong, C H; Blackshaw, P E; Ng, K H; Abdullah, B J J; Blaauw, M; Dansereau, R J; Perkins, A C.
Afiliação
  • Yeong CH; Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
Appl Radiat Isot ; 69(9): 1181-4, 2011 Sep.
Article em En | MEDLINE | ID: mdl-21550260
Neutron activation of Sm-152 offers a method of radiolabeling for the in vivo study of oral dose formulations by gamma scintigraphy. Reproducibility measurements are needed to ensure the robustness of clinical studies. 204 enteric-coated guaifenesin core tablets (10mg of Sm(2)O(3)) were irradiated by thermal neutrons to achieve 1 MBq at 48 h. Administered activities were 0.86±0.03 MBq. Good reproducibility (CV=3.5%) was observed over 24 weeks ensuring that volunteer doses were within the dose reference level of 0.8 mSv.