Highly sensitive LC-MS/MS-ESI method for simultaneous quantitation of albendazole and ricobendazole in rat plasma and its application to a rat pharmacokinetic study.
Biomed Chromatogr
; 26(2): 247-55, 2012 Feb.
Article
em En
| MEDLINE
| ID: mdl-21633966
ABSTRACT
A highly sensitive and specific LC-MS/MS-ESI method was developed for simultaneous quantification of albenadazole (ABZ) and ricobendazole (RBZ) in rat plasma (50 µL) using phenacetin as an internal standard (IS). Simple protein precipitation was used to extract ABZ and RBZ from rat plasma. The chromatographic resolution of ABZ, RBZ and IS was achieved with a mobile phase consisting of 5 m m ammonium acetate (pH 6) and acetonitrile (2080, v/v) at a flow rate of 1 mL/min on a Chromolith RP-18e column. The total chromatographic run time was 3.5 min and the elution of ABZ, RBZ and IS occurred at 1.66, 1.50 and 1.59 min, respectively. A linear response function was established for the ranges of concentrations 2.01-2007 and 6.02-6020 ng/mL for ABZ and RBZ, respectively. The intra- and inter-day precision values for ABZ and RBZ met the acceptance as per FDA guidelines. ABZ and RBZ were stable in battery of stability studies, viz. bench-top, auto-sampler and freeze-thaw cycles. The developed assay was applied to a pharmacokinetic study in rats.
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Albendazol
/
Cromatografia Líquida
/
Espectrometria de Massas em Tandem
Tipo de estudo:
Diagnostic_studies
/
Prognostic_studies
Limite:
Animals
Idioma:
En
Ano de publicação:
2012
Tipo de documento:
Article