Propensity-matched patient-level comparison of the TAXUS Liberté and TAXUS element (ION) paclitaxel-eluting stents.
Kereiakes, Dean J; Cannon, Louis A; Ormiston, John A; Turco, Mark A; Mann, Tift; Mishkel, Gregory J; McGarry, Thomas; Wang, Hong; Underwood, Paul; Dawkins, Keith D.
Afiliação
  • Kereiakes DJ; The Christ Hospital Heart and Vascular Center/The Lindner Center for Research and Education at The Christ Hospital, Cincinnati, Ohio, USA.
Am J Cardiol ; 108(6): 828-37, 2011 Sep 15.
Article em En | MEDLINE | ID: mdl-21803319
Stent design, metal alloy composition, and strut thickness may influence late lumen loss and clinical outcomes after bare metal stent deployment; however, their impact on outcomes after drug-eluting stent deployment is unknown. Although the TAXUS Liberté and ION paclitaxel-eluting stents use similar polymer and drug, the ION stent incorporates a novel thin-strut platinum chromium metal alloy and cell design. We therefore compared patient-level data from 2,298 subjects enrolled into the TAXUS ATLAS (TAXUS Liberté) and PERSEUS (ION) clinical trials. Propensity-score (1:1) matching was performed to adjust for covariate imbalance between stent types. Twelve-month major adverse cardiac events were less frequent after use of the ION compared to the TAXUS Liberté (12.7% vs 8.3%, p <0.001, unadjusted; 12.0% vs 7.5%, p = 0.007, propensity matched) largely because of decreased non-Q-wave myocardial infarction (MI; 2.9% vs 1.4%, p = 0.01, unadjusted; 3.2% vs 0.9%, p = 0.004, propensity matched). The MI difference was predominantly periprocedural and in patients treated with a single stent. In conclusion, this exploratory post hoc analysis demonstrated that the ION was associated with fewer adverse clinical events than the TAXUS Liberté because of decreased non-Q-wave MI. Stent platform-related variables may influence clinical outcomes after drug-eluting stent use despite similar polymer and drug elution. Differences in adjunctive pharmacotherapy and/or stenting technique may also be contributory.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Paclitaxel / Reestenose Coronária / Moduladores de Tubulina / Stents Farmacológicos / Infarto do Miocárdio Tipo de estudo: Clinical_trials / Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Paclitaxel / Reestenose Coronária / Moduladores de Tubulina / Stents Farmacológicos / Infarto do Miocárdio Tipo de estudo: Clinical_trials / Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2011 Tipo de documento: Article