Improvements in high-field localized MRS of the medial temporal lobe in humans using new deformable high-dielectric materials.
Snaar, J E M; Teeuwisse, W M; Versluis, M J; van Buchem, M A; Kan, H E; Smith, N B; Webb, A G.
Afiliação
  • Snaar JE; C. J. Gorter Center for High Field MRI, Leiden University Medical Center, Leiden, the Netherlands.
NMR Biomed ; 24(7): 873-9, 2011 Aug.
Article em En | MEDLINE | ID: mdl-21834010
ABSTRACT
The intrinsic nonuniformities in the transmit radiofrequency field from standard quadrature volume resonators at high field are particularly problematic for localized MRS in areas such as the temporal lobe, where a low signal-to-noise ratio and poor metabolite quantification result from destructive B1⁺ field interference, in addition to line broadening and signal loss from strong susceptibility gradients. MRS of the temporal lobe has been performed in a number of neurodegenerative diseases at clinical fields, but a relatively low signal-to-noise ratio has prevented the reliable quantification of, for example, glutamate and glutamine, which are thought to play a key role in disease progression. Using a recently developed high-dielectric-constant material placed around the head, localized MRS of the medial temporal lobe using the stimulated echo acquisition mode sequence was acquired at 7 T. The presence of the material increased the signal-to-noise ratio of MRS by a factor of two without significantly reducing the sensitivity in other areas of the brain, as shown by the measured B1⁺ maps. An increase in the receive sensitivity B1⁻ was also measured close to the pads. The spectral linewidth of the unsuppressed water peak within the voxel of interest was reduced slightly by the introduction of the dielectric pads (although not to a statistically significant degree), a result confirmed by using a pad composed of lipid. Using LCmodel for quantitative analysis of metabolite concentrations, the increase in signal-to-noise ratio and the slight decrease in spectral linewidth contributed to statistically significant reductions in the Cramer-Rao lower bounds (CRLBs), also allowing the levels of glutamate and glutamine to be quantified with CRLBs below 20%.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lobo Temporal / Espectroscopia de Ressonância Magnética Limite: Adult / Humans / Middle aged Idioma: En Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lobo Temporal / Espectroscopia de Ressonância Magnética Limite: Adult / Humans / Middle aged Idioma: En Ano de publicação: 2011 Tipo de documento: Article