Your browser doesn't support javascript.
loading
An anatomic study of coronoid cartilage thickness with special reference to fractures.
Rafehi, Samah; Lalone, Emily; Johnson, Marjorie; King, Graham J W; Athwal, George S.
Afiliação
  • Rafehi S; Department of Anatomy and Cell Biology, University of Western Ontario, London, Ontario, Canada.
J Shoulder Elbow Surg ; 21(7): 961-8, 2012 Jul.
Article em En | MEDLINE | ID: mdl-21885303
ABSTRACT

BACKGROUND:

Current coronoid fracture classification systems are based on fragment size and configuration using plain radiographs and/or computed tomography (CT). During surgery, coronoid fracture fragments appear much larger than anticipated because cartilage is radiolucent and therefore not accounted for with preoperative imaging. The purpose of this imaging study was to quantify the articular cartilage thickness of the coronoid, with reference to coronoid fractures. MATERIALS AND

METHODS:

Twenty-four cadaveric ulnae were dissected, imaged with CT, and analyzed by use of image analysis software. Thirteen identifiable landmarks were chosen on the coronoid, olecranon, and proximal radioulnar joint to measure articular cartilage thickness. Intraobserver reliability and interobserver reliability were determined.

RESULTS:

Cartilage thickness was highest at the coronoid tip, with a mean of 3.0 mm (range, 1.7-4.6 mm). Cartilage thickness at the tip correlated inversely with age (P < .01) and correlated strongly with overall ulnar height and ulnar length (P < .05). All measurements had excellent intraobserver and interobserver reliability.

CONCLUSION:

The thickness of cartilage on the coronoid tip is not inconsequential. The results of this study indicate that a 2-mm coronoid tip fracture on CT scan may actually appear to be a mean of 5 mm thick when viewed at the time of surgery. Clinically, this is important because it may alter the classification, the decision to treat, or the type of fixation used. Importantly, biomechanical cadaveric studies assessing coronoid injuries have incorporated cartilage thickness into coronoid size measurements when creating simulated fractures; therefore, it is critical that the conclusions of such biomechanical studies be scrutinized with regard to their clinical recommendations. Surgeons should be aware of these discrepancies.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ulna / Cartilagem Articular / Imageamento Tridimensional / Articulação do Cotovelo Tipo de estudo: Guideline / Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ulna / Cartilagem Articular / Imageamento Tridimensional / Articulação do Cotovelo Tipo de estudo: Guideline / Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article