Your browser doesn't support javascript.
loading
Cardiac resynchronization therapy after coronary sinus lead extraction: feasibility and mid-term outcome of transvenous reimplantation in a tertiary referral centre.
Zucchelli, Giulio; Bongiorni, Maria Grazia; Di Cori, Andrea; Soldati, Ezio; Solarino, Gianluca; Fabiani, Iacopo; Segreti, Luca; De Lucia, Raffaele; Viani, Stefano; Coluccia, Giovanni; Paperini, Luca.
Afiliação
  • Zucchelli G; Department of Cardiovascular Diseases, University Hospital of Pisa, Via Roma 67, Pisa, Italy. zucchelli7@interfree.it
Europace ; 14(4): 515-21, 2012 Apr.
Article em En | MEDLINE | ID: mdl-22037541
ABSTRACT

AIMS:

Few data are available on cardiac resynchronization therapy (CRT) after coronary sinus (CS) lead extraction. We aimed to evaluate the feasibility and mid-term outcome of transvenous CS lead reimplantation in a tertiary referral centre. METHODS AND

RESULTS:

We enrolled all patients who were referred to our hospital for CS lead removal from December 2000 through to May 2009 and were transvenously reimplanted with a CRT system before June 2009. One-year follow-up was performed to evaluate the incidence of infections, malfunctions, and mortality. We studied 113 consecutive patients undergoing successful CS lead extraction; 90 patients (75 male, mean age 69.2, range 35-84) underwent CS lead reimplantation (success rate 95.6%; right-sided

approach:

64.4%). In these patients, cardiac device infection was the usual indication for extraction (74.4%) and the subsequent reimplantation was performed after a median time of 3 days. The coronary sinus lead was usually positioned in the left ventricular (LV) postero-lateral region (62.2%); two procedures were required in two cases (2.2%). Balloon angioplasty was necessary for two patients (failure in one), whereas for the others we used a conventional implant technique. During follow-up, we observed four cases (4.4%) of local infection and six cases (6.7%) of system malfunction, requiring reintervention (two cases during the same hospitalization). One-year mortality was 5.5%.

CONCLUSION:

Left ventricular lead reimplantation is in our experience an effective and safe procedure, also in the case of right-sided approach. During follow-up, 1-year mortality was particularly low, whereas overall infection rate was higher than first implant procedures.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Implantação de Prótese / Eletrodos Implantados / Seio Coronário / Terapia de Ressincronização Cardíaca Tipo de estudo: Etiology_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Arritmias Cardíacas / Implantação de Prótese / Eletrodos Implantados / Seio Coronário / Terapia de Ressincronização Cardíaca Tipo de estudo: Etiology_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2012 Tipo de documento: Article