Interference by o-phenanthroline in the radioimmunoassay of angiotensin II in small volume blood samples.
Clin Biochem
; 45(1-2): 168-70, 2012 Jan.
Article
em En
| MEDLINE
| ID: mdl-22040809
OBJECTIVES: To investigate the ratio of enzyme inhibitor volume to blood volume in angiotensin II (Ang II) blood collection tubes. DESIGN AND METHODS: Whole blood was mixed with known volumes of inhibitor prior to angiotensin II analysis. RESULTS: Imunoreactive Ang II levels increased at low blood volume to high inhibitor volume ratios, due to interference by o-phenanthroline. CONCLUSION: To prevent falsely elevated Ang II levels in low volume blood samples an appropriate volume of inhibitor solution must be used.