Accuracy of GFR predictive equations in renal transplantation: validation of a new turbidimetric cystatin C assay on Architect c8000.
Bargnoux, A S; Servel, A C; Piéroni, L; Dupuy, A M; Badiou, S; Garrigue, V; Mourad, G; Cristol, J P.
Afiliação
  • Bargnoux AS; Department of Biochemistry, University of Montpellier 1, Montpellier, France.
Clin Biochem ; 45(1-2): 151-3, 2012 Jan.
Article em En | MEDLINE | ID: mdl-22079396
ABSTRACT

OBJECTIVES:

To evaluate the Sentinel-PETIA cystatin C on Architect c8000 analyzer. DESIGN AND

METHODS:

We assessed analytical performances and clinical relevance by comparison with a reference isotopic method in kidney transplant recipients.

RESULTS:

This assay exhibited reliable precision and was close to the non standardized Siemens-PENIA method. All tested equations allowed reliable assessment of GFR.

CONCLUSIONS:

Cystatin C improved GFR determination at the critical level of 60 mL/min/1.73 m². New formulas might be necessary after IFCC standardization.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transplante de Rim / Cistatina C / Taxa de Filtração Glomerular / Nefelometria e Turbidimetria Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transplante de Rim / Cistatina C / Taxa de Filtração Glomerular / Nefelometria e Turbidimetria Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article