Your browser doesn't support javascript.
loading
Optically transmitted and inductively coupled electric reference to access in vivo concentrations for quantitative proton-decoupled ¹³C magnetic resonance spectroscopy.
Chen, Xing; Pavan, Matteo; Heinzer-Schweizer, Susanne; Boesiger, Peter; Henning, Anke.
Afiliação
  • Chen X; Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland. chen@biomed.ee.ethz.ch
Magn Reson Med ; 67(1): 1-7, 2012 Jan.
Article em En | MEDLINE | ID: mdl-22084025
ABSTRACT
This report describes our efforts on quantification of tissue metabolite concentrations in mM by nuclear Overhauser enhanced and proton decoupled (13) C magnetic resonance spectroscopy and the Electric Reference To access In vivo Concentrations (ERETIC) method. Previous work showed that a calibrated synthetic magnetic resonance spectroscopy-like signal transmitted through an optical fiber and inductively coupled into a transmit/receive coil represents a reliable reference standard for in vivo (1) H magnetic resonance spectroscopy quantification on a clinical platform. In this work, we introduce a related implementation that enables simultaneous proton decoupling and ERETIC-based metabolite quantification and hence extends the applicability of the ERETIC method to nuclear Overhauser enhanced and proton decoupled in vivo (13) C magnetic resonance spectroscopy. In addition, ERETIC signal stability under the influence of simultaneous proton decoupling is investigated. The proposed quantification method was cross-validated against internal and external reference standards on human skeletal muscle. The ERETIC signal intensity stability was 100.65 ± 4.18% over 3 months including measurements with and without proton decoupling. Glycogen and unsaturated fatty acid concentrations measured with the ERETIC method were in excellent agreement with internal creatine and external phantom reference methods, showing a difference of 1.85 ± 1.21% for glycogen and 1.84 ± 1.00% for unsaturated fatty acid between ERETIC and creatine-based quantification, whereas the deviations between external reference and creatine-based quantification are 6.95 ± 9.52% and 3.19 ± 2.60%, respectively.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectroscopia de Ressonância Magnética / Músculo Esquelético / Ácidos Graxos Insaturados / Tecnologia de Fibra Óptica / Glicogênio / Magnetismo Tipo de estudo: Evaluation_studies / Guideline Limite: Humans Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectroscopia de Ressonância Magnética / Músculo Esquelético / Ácidos Graxos Insaturados / Tecnologia de Fibra Óptica / Glicogênio / Magnetismo Tipo de estudo: Evaluation_studies / Guideline Limite: Humans Idioma: En Ano de publicação: 2012 Tipo de documento: Article