Your browser doesn't support javascript.
loading
Temporally resolved electrocardiogram-triggered diffusion-weighted imaging of the human kidney: correlation between intravoxel incoherent motion parameters and renal blood flow at different time points of the cardiac cycle.
Wittsack, Hans-Jörg; Lanzman, Rotem S; Quentin, Michael; Kuhlemann, Julia; Klasen, Janina; Pentang, Gael; Riegger, Caroline; Antoch, Gerald; Blondin, Dirk.
Afiliação
  • Wittsack HJ; Department of Diagnostic and Interventional Radiology, University Düsseldorf, Düsseldorf, Germany. wittsack@uni-duesseldorf.de
Invest Radiol ; 47(4): 226-30, 2012 Apr.
Article em En | MEDLINE | ID: mdl-22104959
ABSTRACT

PURPOSE:

To evaluate the influence of pulsatile blood flow on apparent diffusion coefficients (ADC) and the fraction of pseudodiffusion (F(P)) in the human kidney. MATERIALS AND

METHODS:

The kidneys of 6 healthy volunteers were examined by a 3-T magnetic resonance scanner. Electrocardiogram (ECG)-gated and respiratory-triggered diffusion-weighted imaging (DWI) and phase-contrast flow measurements were performed. Flow imaging of renal arteries was carried out to quantify the dependence of renal blood flow on the cardiac cycle. ECG-triggered DWI was acquired in the coronal plane with 16 b values in the range of 0 s/mm(2) and 750 s/mm(2) at the time of minimum (MIN) (20 milliseconds after R wave) and maximum renal blood flow (MAX) (197 ± 24 milliseconds after R wave). The diffusion coefficients were calculated using the monoexponential approach as well as the biexponential intravoxel incoherent motion model and correlated to phase-contrast flow measurements.

RESULTS:

Flow imaging showed pulsatile renal blood flow depending on the cardiac cycle. The mean flow velocity at MIN was 45 cm/s as compared with 61 cm/s at MAX. F(p) at MIN (0.29) was significantly lower than at MAX (0.40) (P = 0.001). Similarly, ADC(mono), derived from the monoexponential model, also showed a significant difference (P < 0.001) between MIN (ADC(mono) = 2.14 ± 0.08 × 10(-3) mm(2)/s) and MAX (ADC(mono) = 2.37 ± 0.04 × 10(-3) mm(2)/s). The correlation between renal blood flow and F(p) (r = 0.85) as well as ADC(mono) (r = 0.67) was statistically significant.

CONCLUSION:

Temporally resolved ECG-gated DWI enables for the determination of the diffusion coefficients at different time points of the cardiac cycle. ADC(mono) and FP vary significantly among acquisitions at minimum (diastole) and maximum (systole) renal blood flow. Temporally resolved ECG-gated DWI might therefore serve as a novel technique for the assessment of pulsatility in the human kidney.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Circulação Renal / Fluxo Pulsátil / Interpretação de Imagem Assistida por Computador / Angiografia por Ressonância Magnética / Técnicas de Imagem de Sincronização Cardíaca / Frequência Cardíaca Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Circulação Renal / Fluxo Pulsátil / Interpretação de Imagem Assistida por Computador / Angiografia por Ressonância Magnética / Técnicas de Imagem de Sincronização Cardíaca / Frequência Cardíaca Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2012 Tipo de documento: Article