Your browser doesn't support javascript.
loading
Microelectromechanical-systems-driven two-layer rotary-blade-based adjustable iris diaphragm.
Zhou, Guangya; Yu, Hongbin; Du, Yu; Chau, Fook Siong.
Afiliação
  • Zhou G; Department of Mechanical Engineering, National University of Singapore, Singapore. mpezgy@nus.edu.sg
Opt Lett ; 37(10): 1745-7, 2012 May 15.
Article em En | MEDLINE | ID: mdl-22627557
ABSTRACT
We report a miniature adjustable multi-blade iris diaphragm driven by microelectromechanical-systems-based electrostatic rotary microactuators. A proof-of-concept device is designed and fabricated using a silicon-on-insulator micromachining process. The diameter of the developed iris diaphragm aperture is experimentally demonstrated to be able to adjust from 0.45 to 1.56 mm. When used in a miniature camera lens system, the current prototype device is capable of providing an adjustment range of more than three full f/stops.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2012 Tipo de documento: Article