Your browser doesn't support javascript.
loading
Three-dimensional brain phantom containing bone and grey matter structures with a realistic head contour.
Iida, Hidehiro; Hori, Yuki; Ishida, Kenji; Imabayashi, Etsuko; Matsuda, Hiroshi; Takahashi, Masaaki; Maruno, Hirotaka; Yamamoto, Akihide; Koshino, Kazuhiro; Enmi, Junichiro; Iguchi, Satoshi; Moriguchi, Tetsuaki; Kawashima, Hidekazu; Zeniya, Tsutomu.
Afiliação
  • Iida H; Department of Investigative Radiology, National Cerebral and Cardiovascular Center Research Institute, Suita City, Osaka, Japan. iida@ri.ncvc.go.jp
Ann Nucl Med ; 27(1): 25-36, 2013 Jan.
Article em En | MEDLINE | ID: mdl-23011903
INTRODUCTION: A physical 3-dimensional phantom that simulates PET/SPECT images of static regional cerebral blood flow in grey matter with a realistic head contour has been developed. This study examined the feasibility of using this phantom for evaluating PET/SPECT images. METHODS: The phantom was constructed using a transparent, hydrophobic photo-curable polymer with a laser-modelling technique. The phantom was designed to contain the grey matter, the skull, and the trachea spaces filled with a radioactive solution, a bone-equivalent solution of K(2)HPO(4), and air, respectively. The grey matter and bone compartments were designed to establish the connectivity. A series of experiments was performed to confirm the accuracy and reproducibility of the phantom using X-ray CT, SPECT, and PET. RESULTS: The total weight was 1997 ± 2 g excluding the inner liquid, and volumes were 563 ± 1 and 306 ± 2 mL, corresponding to the grey matter and bone compartments, respectively. The apparent attenuation coefficient averaged over the whole brain was 0.168 ± 0.006 cm(-1) for Tc-99 m, which was consistent with the previously reported value for humans (0.168 ± 0.010 cm(-1)). Air bubbles were well removed from both grey-matter and bone compartments, as confirmed by X-ray CT. The phantom was well adapted to experiments using PET and SPECT devices. CONCLUSION: The 3-dimensional brain phantom constructed in this study may be of use for evaluating the adequacy of SPECT/PET reconstruction software programs.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Crânio / Encéfalo / Imagens de Fantasmas / Imageamento Tridimensional / Cabeça Limite: Humans Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Crânio / Encéfalo / Imagens de Fantasmas / Imageamento Tridimensional / Cabeça Limite: Humans Idioma: En Ano de publicação: 2013 Tipo de documento: Article