Zirconia posterior fixed partial dentures: 5-year clinical results of a prospective clinical trial.
Schmitt, Johannes; Goellner, Matthias; Lohbauer, Ulrich; Wichmann, Manfred; Reich, Sven.
Afiliação
  • Schmitt J; Department of Prosthodontics, Friedrich-Alexander-University, Erlangen, Germany. johannes.schmitt@uk-erlangen.de
Int J Prosthodont ; 25(6): 585-9, 2012.
Article em En | MEDLINE | ID: mdl-23101038
This study aimed to evaluate three- and four-unit posterior fixed partial dentures (FPDs) with zirconia frameworks after 5 years of function. Of the initial 30 subjects, 25 patients with 25 FPDs were examined after a mean follow-up period of 62.1 months. Five patients were not available for recall visits. Two FPDs failed before the 60-month evaluation because of framework fracture or delamination of the veneering ceramic after endodontic treatment. The 5-year survival rate was 92%. Based on these results, it can be suggested that zirconia frameworks have sufficient mechanical requirements for use in the stress-bearing posterior region. Major fracture of the ceramic veneer could be related to inadequate framework design or bruxism.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Zircônio / Prótese Parcial Tipo de estudo: Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article