Use of a combined SpO2/PtcCO2 sensor in the delivery room.
Rubortone, Serena Antonia; De Carolis, Maria Pia; Lacerenza, Serafina; Bersani, Iliana; Occhipinti, Federica; Romagnoli, Costantino.
Afiliação
  • Rubortone SA; Division of Neonatology, Department of Paediatrics, Catholic University of Sacred Heart, Largo Gemelli 8, I-00168 Rome, Italy. sererubor@hotmail.it
Sensors (Basel) ; 12(8): 10980-9, 2012.
Article em En | MEDLINE | ID: mdl-23112642
ABSTRACT
Arterial oxygen saturation (SaO(2)) and partial arterial pressure of carbon dioxide (PaCO(2)) are important respiratory parameters in critically ill neonates. A sensor combining a pulse oximeter with the Stow-Severinghaus electrode, required for the measurement of peripheral oxygen saturation (SpO(2)) and transcutaneous partial pressure of carbon dioxide (PtcCO(2)), respectively, has been recently used in neonatal clinical practice (TOSCA(500Ò)Radiometer). We evaluated TOSCA usability and reliability in the delivery room (DR), throughout three different periods, on term, late-preterm, and preterm neonates. During the first period (period A), 30 healthy term neonates were simultaneously monitored with both TOSCA and a MASIMO pulse oximeter. During the second period (period B), 10 healthy late-preterm neonates were monitored with both TOSCA and a transcutaneous device measuring PtcCO(2) (TINA(Ò) TCM3, Radiometer). During the third period (period C), 15 preterm neonates were monitored with TOSCA and MASIMO after birth, during stabilization, and during transport to the neonatal intensive care unit (NICU). Blood gas analyses were performed to compare transcutaneous and blood gas values. TOSCA resulted easily and safely usable in the DR, allowing reliable noninvasive SaO(2) estimation. Since PtcCO(2) measurements with TOSCA required at least 10 min to be stable and reliable, this parameter was not useful during the early resuscitation immediately after birth. Moreover, PtcCO(2) levels were less precise if compared to the conventional transcutaneous monitoring. However, PtcCO(2) measurement by TOSCA was useful as trend-monitoring after stabilization and during transport to NICU.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Monitorização Transcutânea dos Gases Sanguíneos / Dióxido de Carbono Tipo de estudo: Observational_studies Limite: Female / Humans / Male / Newborn Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Monitorização Transcutânea dos Gases Sanguíneos / Dióxido de Carbono Tipo de estudo: Observational_studies Limite: Female / Humans / Male / Newborn Idioma: En Ano de publicação: 2012 Tipo de documento: Article