Double Bolus Application in TWIST-MR-Angiography of the Cervical Arteries.
Korn, Andreas; Fenchel, Michael; Hauser, Till-Karsten; Bisdas, Sotirios; Nägele, Thomas; Ernemann, Ulrike; Klose, Uwe; Bender, Benjamin.
Afiliação
  • Korn A; Department of Diagnostic and Interventional Neuroradiology, University of Tübingen, Hoppe-Seyler Street 3, 72076 Tübingen, Germany.
Radiol Res Pract ; 2012: 203538, 2012.
Article em En | MEDLINE | ID: mdl-23125928
Purpose. The aim of the present work was to test the feasibility of the time-resolved MR-angiography (TWIST-MRA) of cervical arteries using double bolus injection. Material and Methods. TWIST-MRA with a temporal resolution of 8.4 seconds for each frame and a spatial resolution with a voxel size of 0.61 × 0.58 × 0.8 mm(3) was performed in 24 patients. A biphasic bolus injection protocol was used with the second injection being started 21 seconds after the first contrast dye bolus. Diagnostic image quality was rated according to a 4-point scale. Results. In 12 patients (50%) no clear separation between the cervical venous and arterial vessels was evident after the first bolus injection. Using TWIST-MRA data acquired after the second bolus a sufficient diagnostic image quality (rating ≥3, mean 3.5) could be obtained in 22 of 24 patients (92%). Discussion. The double bolus injection protocol using TWIST-MRA allows for very good separation of the cervical arteries.

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Ano de publicação: 2012 Tipo de documento: Article