Your browser doesn't support javascript.
loading
Upgrade of the infrared camera diagnostics for the JET ITER-like wall divertor.
Balboa, I; Arnoux, G; Eich, T; Sieglin, B; Devaux, S; Zeidner, W; Morlock, C; Kruezi, U; Sergienko, G; Kinna, D; Thomas, P D; Rack, M.
Afiliação
  • Balboa I; EURATOM∕CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB, United Kingdom. itziar.balboa@ccfe.ac.uk
Rev Sci Instrum ; 83(10): 10D530, 2012 Oct.
Article em En | MEDLINE | ID: mdl-23130793
For the new ITER-like wall at JET, two new infrared diagnostics (KL9B, KL3B) have been installed. These diagnostics can operate between 3.5 and 5 µm and up to sampling frequencies of ∼20 kHz. KL9B and KL3B image the horizontal and vertical tiles of the divertor. The divertor tiles are tungsten coated carbon fiber composite except the central tile which is bulk tungsten and consists of lamella segments. The thermal emission between lamellae affects the surface temperature measurement and therefore KL9A has been upgraded to achieve a higher spatial resolution (by a factor of 2). A technical description of KL9A, KL9B, and KL3B and cross correlation with a near infrared camera and a two-color pyrometer is presented.

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2012 Tipo de documento: Article