Your browser doesn't support javascript.
loading
Cardiovascular CT angiography in neonates and children: image quality and potential for radiation dose reduction with iterative image reconstruction techniques.
Tricarico, Francesco; Hlavacek, Anthony M; Schoepf, U Joseph; Ebersberger, Ullrich; Nance, John W; Vliegenthart, Rozemarijn; Cho, Young Jun; Spears, J Reid; Secchi, Francesco; Savino, Giancarlo; Marano, Riccardo; Schoenberg, Stefan O; Bonomo, Lorenzo; Apfaltrer, Paul.
Afiliação
  • Tricarico F; Department of Radiology and Radiological Science, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive, MSC 226, Charleston, SC 29401, USA.
Eur Radiol ; 23(5): 1306-15, 2013 May.
Article em En | MEDLINE | ID: mdl-23207869
OBJECTIVES: To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. METHODS: Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. RESULTS: Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P < 0.001), while SNR and CNR were higher (P < 0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P < 0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P < 0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. CONCLUSIONS: IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. KEY POINTS: • Iterative reconstruction techniques significantly improve non-invasive cardiovascular CT in children. • Using half traditional radiation dose image quality is higher with iterative reconstruction. • Iterative reconstruction techniques may allow further radiation reductions in paediatric cardiovascular CT.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doses de Radiação / Proteção Radiológica / Interpretação de Imagem Radiográfica Assistida por Computador / Doenças Cardiovasculares / Tomografia Computadorizada por Raios X / Angiografia Coronária Tipo de estudo: Diagnostic_studies Limite: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doses de Radiação / Proteção Radiológica / Interpretação de Imagem Radiográfica Assistida por Computador / Doenças Cardiovasculares / Tomografia Computadorizada por Raios X / Angiografia Coronária Tipo de estudo: Diagnostic_studies Limite: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male / Newborn Idioma: En Ano de publicação: 2013 Tipo de documento: Article