A comprehensive framework for the detection of individual brain perfusion abnormalities using arterial spin labeling.
Med Image Comput Comput Assist Interv
; 15(Pt 3): 542-9, 2012.
Article
em En
| MEDLINE
| ID: mdl-23286173
Arterial spin labeling (ASL) enables measuring cerebral blood flow in MRI without injection of a contrast agent. Perfusion measured by ASL carries relevant information for patients suffering from pathologies associated with singular perfusion patterns. However, to date, individual identification of abnormal perfusion patterns in ASL usually relies on visual inspection or manual delineation of regions of interest. In this paper, we introduce a new framework to automatically outline patterns of abnormal perfusion in individual patients by means of an ASL template. We compare two models of normal perfusion and assess the quality of detections comparing an a contrario approach to the generalized linear model (GLM).
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Algoritmos
/
Interpretação de Imagem Assistida por Computador
/
Transtornos Cerebrovasculares
/
Angiografia por Ressonância Magnética
Tipo de estudo:
Diagnostic_studies
/
Prognostic_studies
Limite:
Humans
Idioma:
En
Ano de publicação:
2012
Tipo de documento:
Article