Your browser doesn't support javascript.
loading
Quantitative assessment of late lumen loss after biodegradable polymer and permanent polymer sirolimus-eluting stents implantation.
Kan, Jing; Chen, Feng; Liu, Li-Ya; Xu, Hai-Mei; Lin, Ling; Liu, Yan; Zhao, Ying-Ying; Cheng, Jiu-Pei; Chen, Shao-Liang.
Afiliação
  • Kan J; Department of Cardiology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu 210006, China.
Chin Med J (Engl) ; 126(6): 1081-5, 2013 Mar.
Article em En | MEDLINE | ID: mdl-23506582
ABSTRACT

BACKGROUND:

Sirolimus-eluting stents (SES) are reported to be associated with reduced late lumen loss (LLL), resulting in less frequent restenosis when compared to bare-metal stent. The current study aimed to assess the difference in LLL between SES with biodegradable and with permanent polymer.

METHODS:

From March 2010 to June 2011, 300 consecutive patients having only biodegradable polymers or permanent polymer SES for all diseased vessels were included. Serial quantitative coronary analysis was performed on both the "in-stent" and "segment" area, including the stented segment, as well as both five mm margins proximal and distal to the stent. The primary endpoint was the LLL defined as the minimal lumen diameter (MLD) post-stenting minus the MLD at nine-month after the indexed procedure.

RESULTS:

LLL was comparable between the two stents. Importantly, LLL for the distal segment (median 0.05 mm, interquartile 0 to 0.09 mm) was less severe compared with in-stent (median 0.13 mm, interquartile 0.08 to 0.18 mm) and proximal segment LLL (median 0.12 mm, interquartile 0.06 to 0.14 mm, all P < 0.001). In general, the LLL was associated with the post-procedure MLD (b = 0.28, P = 0.002), hyperlipidemia (b = 0.14, P = 0.021), and calcified lesions (b = 0.58, P = 0.001). The R(2) and Radj of the multiple regression model were 0.651 and 0.625, respectively.

CONCLUSIONS:

SES with either biodegradable or permanent polymer had lower value of LLL. The small amount of LLL at the distal segment possibly contributed to the less distal edge stenosis.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Polímeros / Sirolimo / Stents Farmacológicos Tipo de estudo: Diagnostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2013 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Polímeros / Sirolimo / Stents Farmacológicos Tipo de estudo: Diagnostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2013 Tipo de documento: Article