ABSTRACT

PURPOSE:

This study was designed to compare the radiation dose in abdominal dual-energy (DE) and single-energy (SE) acquisitions obtained in clinical practice with a second-generation DE computed tomography (DECT) and to analyze the dose variation in comparison with an SE acquisition performed with a 64-row SECT (SECT).

METHODS:

A total of 130 patients divided into 2 groups underwent precontrast and portal abdominal 128-row CT examination. In group A, DE portal acquisition was performed using a detector configuration of 2 × 40 × 0.6 mm, tube A at 80 kVp and a reference value of 559 mAs, tube B at 140 kVp and a reference value of 216 mAs, pitch 0.6, and online dose modulation; group B underwent SE portal acquisition using a detector configuration of 64 × 0.6 mm, 120 kVp and a reference value of 180 mAs, pitch 0.75, and online dose modulation. Group C consisted of 32 subjects from group A previously studied with 64-row SECT using the following parameters detector configuration 64 × 0.6 mm, 120 kVp and a reference value of 180 mAs, pitch 0.75, and online dose modulation. In each group, the portal phase dose-length product and radiation dose (mSv) were calculated and normalized for a typical abdominal acquisition of 40 cm.

RESULTS:

After normalization to standard 40-cm acquisition, a dose-length product of 599.0 ± 133.5 mGy · cm (range, 367.5 ± 1231.2 mGy · cm) in group A, 525.9 ± 139.2 mGy · cm (range, 215.7-882.8 mGy · cm) in group B, and 515.9 ± 111.3 mGy · cm (range, 305.5-687.2 mGy · cm) in group C was calculated for portal phase acquisition.A significant radiation dose increase (P < 0.05) was observed in group A (10.2 ± 2.3 mSv) compared with group B (8.9 ± 2.4) and group C (8.8 ± 1.9 mSv). No significant difference (P > 0.05) was reported between SE 64- and 128-row acquisitions. A significant positive correlation between radiation dose and body mass index was observed in each group (group A, r = 0.59, P < 0.0001; group B, r = 0.35, P < 0.0001; group C, r = 0.20, P = 0.0098).

CONCLUSIONS:

In clinical practice, abdominal DECT acquisition shows a significant but minimal radiation dose increase, on the order of 1 mSv, compared with 64- and 128-row SE acquisition. The slightly increased radiation dose can be justified if the additional information obtained using a spectral imaging approach directly impacts on patient management or reduce the overall radiation dose with the generation of virtual unenhanced images, which can replace the precontrast acquisition.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doses de Radiação / Carga Corporal (Radioterapia) / Radiografia Abdominal / Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doses de Radiação / Carga Corporal (Radioterapia) / Radiografia Abdominal / Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2013 Tipo de documento: Article