Your browser doesn't support javascript.
loading
Clinical and technical factors associated with skin intrinsic fluorescence in subjects with type 1 diabetes from the Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications Study.
Cleary, Patricia A; Braffett, Barbara H; Orchard, Trevor; Lyons, Timothy J; Maynard, John; Cowie, Catherine; Gubitosi-Klug, Rose A; Way, Jeff; Anderson, Karen; Barnie, Annette; Villavicencio, Stephan.
Afiliação
  • Cleary PA; George Washington University, Rockville, Maryland 20852, USA. cleary@bsc.gwu.edu
Diabetes Technol Ther ; 15(6): 466-74, 2013 Jun.
Article em En | MEDLINE | ID: mdl-23882708
BACKGROUND: The Diabetes Control and Complications Trial (DCCT)/Epidemiology of Diabetes Interventions and Complications(EDIC) studies have established multiyear mean hemoglobin A1c (HbA1c) as predictive of microvascular complications in persons with type 1 diabetes. However, multiyear mean HbA1c is not always available in the clinical setting. Skin advanced glycation end products (AGEs) are thought to partially reflect effects of hyperglycemia over time, and measurement of skin AGEs might be a surrogate for multiyear mean HbA1c. As certain AGEs fluoresce and skin fluorescence has been demonstrated to correlate with the concentration of skin AGEs, noninvasive measurement by skin intrinsic fluorescence(SIF) facilitates the exploration of the association of mean HbA1c and other clinical/technical factors with SIF using the detailed phenotypic database available in DCCT/EDIC. SUBJECTS AND METHODS: Of the subjects, 1,185 (53% male) had measurements of SIF during years 16/17 of EDIC with mean age and diabetes duration of 51.5 and 29.8 years, respectively. SIF measurements were obtained on the underside of the forearm near the elbow using a skin fluorescence spectrometer. Demographic data and health history were self-reported, and an annual standardized examination measured clinical status. Linear regression models were constructed to identify significant clinical and technical factors associated with SIF, and the final models only used factors that were significant. RESULTS: SIF ranged from 8.7 to 54.0 arbitrary units and was log-normally distributed. Log(SIF) correlated more with mean HbA1c as the time period increased. In multivariate analyses log(SIF) was significantly associated with mean HbA1c, age,estimated glomerular filtration rate < 60mL/min/m2, smoking status, skin tone, and clinic latitude <37 N. CONCLUSIONS: SIF reflects age, mean HbA1c over time, smoking, and renal damage, which are known risk factors for diabetes complications.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pele / Espectrometria de Fluorescência / Diabetes Mellitus Tipo 1 / Angiopatias Diabéticas / Nefropatias Diabéticas Tipo de estudo: Clinical_trials / Etiology_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pele / Espectrometria de Fluorescência / Diabetes Mellitus Tipo 1 / Angiopatias Diabéticas / Nefropatias Diabéticas Tipo de estudo: Clinical_trials / Etiology_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2013 Tipo de documento: Article