Your browser doesn't support javascript.
loading
Qualification and application of a liquid chromatography-tandem mass spectrometric method for the determination of human Aß1-40 and Aß1-42 peptides in transgenic mouse plasma using micro-elution solid phase extraction.
Shin, Young G; Hamm, Lee; Murakami, Stanley; Buirst, Kenji; Buonarati, Michael H; Cox, April; Regal, Kelly; Hunt, Kevin W; Scearce-Levie, Kimberly; Watts, Ryan J; Liu, Xingrong.
Afiliação
  • Shin YG; Drug Metabolism and Pharmacokinetics, Genentech Inc., 1 DNA Way, Mail Stop 412A, South San Francisco, CA, 94080, USA, yshin@cnu.ac.kr.
Arch Pharm Res ; 37(5): 636-44, 2014 May.
Article em En | MEDLINE | ID: mdl-23888333
A liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method was developed and applied for the determination of human Aß1-40 and Aß1-42 peptides in transgenic mouse plasma to support preclinical pharmacodynamics studies. The method consisted of micro-elution solid phase extraction for sample preparation and LC-MS/MS analysis in the negative ion mode using electrospray ionization for analysis. (15)N53-Aß1-40 and (15)N55-Aß1-42 peptides were used as internal standards. A quadratic regression (weighted 1/concentrations), with an equation y = ax(2) + bx + c, was used to fit calibration curves over the concentration range of 0.500-100 ng/mL for both Aß1-40 and Aß1-42 peptides. For quality control samples at 6.00, 40.0 and 80.0 ng/mL from the qualification experiment, the within-run accuracy ranged from -2.69 to 0.583 % with precision values ≤8.23 % for Aß1-40. Within-run accuracy ranged from -4.83 to 10.1 % with precision values ≤8.87 % for Aß1-42. Samples from a pharmacodynamics study using Tg2576 transgenic mice were analyzed by this qualified LC-MS/MS method and concentrations were compared to those generated by ELISA. The two methods were shown to be comparable for Aß1-40 quantification of samples from the Tg2576 amyloid precursor protein transgenic mouse model, but varied slightly for Aß1-42.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Peptídeos beta-Amiloides / Cromatografia Líquida / Espectrometria de Massas em Tandem / Microextração em Fase Sólida Tipo de estudo: Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Peptídeos beta-Amiloides / Cromatografia Líquida / Espectrometria de Massas em Tandem / Microextração em Fase Sólida Tipo de estudo: Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2014 Tipo de documento: Article