Your browser doesn't support javascript.
loading
Sulfide response analysis for sulfide control using a pS electrode in sulfate reducing bioreactors.
Villa-Gomez, D K; Cassidy, J; Keesman, K J; Sampaio, R; Lens, P N L.
Afiliação
  • Villa-Gomez DK; Chair Group Pollution Prevention and Resource Recovery, UNESCO-IHE Institute for Water Education, P.O. Box 3015, 2601 DA Delft, The Netherlands. Electronic address: denyskristalia@hotmail.com.
  • Cassidy J; Chair Group Pollution Prevention and Resource Recovery, UNESCO-IHE Institute for Water Education, P.O. Box 3015, 2601 DA Delft, The Netherlands.
  • Keesman KJ; Systems and Control Group, Wageningen University, P.O. Box 17, 6700 AA Wageningen, The Netherlands.
  • Sampaio R; Sub-Department of Environmental Technology, Wageningen University, P.O. Box 8129, 6700 EV Wageningen, The Netherlands.
  • Lens PN; Chair Group Pollution Prevention and Resource Recovery, UNESCO-IHE Institute for Water Education, P.O. Box 3015, 2601 DA Delft, The Netherlands.
Water Res ; 50: 48-58, 2014 Mar 01.
Article em En | MEDLINE | ID: mdl-24361702
ABSTRACT
Step changes in the organic loading rate (OLR) through variations in the influent chemical oxygen demand (CODin) concentration or in the hydraulic retention time (HRT) at constant COD/SO4(2-) ratio (0.67) were applied to create sulfide responses for the design of a sulfide control in sulfate reducing bioreactors. The sulfide was measured using a sulfide ion selective electrode (pS) and the values obtained were used to calculate proportional-integral-derivative (PID) controller parameters. The experiments were performed in an inverse fluidized bed bioreactor with automated operation using the LabVIEW software version 2009(®). A rapid response and high sulfide increment was obtained through a stepwise increase in the CODin concentration, while a stepwise decrease to the HRT exhibited a slower response with smaller sulfide increment. Irrespective of the way the OLR was decreased, the pS response showed a time-varying behavior due to sulfide accumulation (HRT change) or utilization of substrate sources that were not accounted for (CODin change). The pS electrode response, however, showed to be informative for applications in sulfate reducing bioreactors. Nevertheless, the recorded pS values need to be corrected for pH variations and high sulfide concentrations (>200 mg/L).
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sulfatos / Sulfetos / Eletrodos Seletivos de Íons / Reatores Biológicos Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sulfatos / Sulfetos / Eletrodos Seletivos de Íons / Reatores Biológicos Idioma: En Ano de publicação: 2014 Tipo de documento: Article