ABSTRACT

BACKGROUND:

Oxidized lipoprotein(a) [ox-Lp(a)] and oxidized low density lipoprotein (ox-LDL) levels have been reported to be useful predictors of cardiovascular events. The study developed a chemiluminescence (CL) imaging immunoassay method for simultaneously detecting serum concentrations of ox-Lp(a) and ox-LDL.

METHODS:

Ox-Lp(a) and ox-LDL levels were measured by CL imaging immunoassay using a disposable immunosensor array as the carrier and a charge-coupled device as the detector, and were studied in 46 acute coronary syndromes (ACS) patients, 58 stable coronary artery disease (CAD) and 61 control subjects.

RESULTS:

This method showed good linear relations (R²>0.99) in the concentration range of 2.00×10⁻5-2.00×10⁻¹ and 2.40×10⁻4-2.40 U/mL for ox-Lp(a) and ox-LDL, respectively. The detection limits for ox-Lp(a) and ox-LDL were 2.40×10⁻6 and 3.00×10⁻5 U/mL, respectively. The intra- and inter-assay coefficients of variation (CV) were 4.90%-6.76% and 7.11%-10.06% for ox-Lp(a), and 5.01%-6.04% and 5.47%-9.77% for ox-LDL, respectively. The mean recovery was 99.31% for ox-Lp(a) and 99.57% for ox-LDL, respectively. Significant correlations were observed between ox-Lp(a) levels detected by CL imaging immunoassay and ELISA, and between ox-LDL levels detected by the two methods, respectively. Furthermore, ox-Lp(a) and ox-LDL levels increased in stable CAD, and especially in ACS.

CONCLUSIONS:

The CL imaging immunoassay provided a simple, sensitive and reliable method for the simultaneous determination of serum ox-Lp(a) and ox-LDL. The clinical monitoring ox-Lp(a) and ox-LDL levels may possess distinctly clinical value for assessment of CAD risk.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Química do Sangue / Imunoensaio / Lipoproteínas LDL / Medições Luminescentes Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Química do Sangue / Imunoensaio / Lipoproteínas LDL / Medições Luminescentes Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2014 Tipo de documento: Article