Your browser doesn't support javascript.
loading
Clinical investigation of a novel surgical device for circumcision.
Yuan, Yiming; Zhang, Zhichao; Cui, Wanshou; Gao, Bing; Peng, Jing; Xin, Zhongcheng; Guo, Yinglu.
Afiliação
  • Yuan Y; Andrology Center of Peking University First Hospital, Beijing, People's Republic of China.
  • Zhang Z; Andrology Center of Peking University First Hospital, Beijing, People's Republic of China. Electronic address: zhangzhichao@bjmu.edu.cn.
  • Cui W; Andrology Center of Peking University First Hospital, Beijing, People's Republic of China.
  • Gao B; Andrology Center of Peking University First Hospital, Beijing, People's Republic of China.
  • Peng J; Andrology Center of Peking University First Hospital, Beijing, People's Republic of China.
  • Xin Z; Andrology Center of Peking University First Hospital, Beijing, People's Republic of China.
  • Guo Y; Andrology Center of Peking University First Hospital, Beijing, People's Republic of China.
J Urol ; 191(5): 1411-5, 2014 May.
Article em En | MEDLINE | ID: mdl-24423436
PURPOSE: We investigated the performance of a novel device for adult circumcision, that is the circular cutter with stapled anastomosis for circumcision. MATERIALS AND METHODS: A total of 62 men with a mean ± SD age of 28 ± 8 years were enrolled from June to September 2012 to undergo circumcision using the circular cutter with stapled anastomosis. The device used 18 staples for anastomosis, which fall out during the recovery course, as designed. Patients were followed at day 3, and weeks 1, 2, 4 and 12 after the procedure. Outcome measures were evaluated, including patient safety, procedural time, patient satisfaction and complication rate. RESULTS: Average procedural time needed to use the device was 7.7 ± 2.6 minutes. Patients returned to full physical activity on postoperative day 3. The overall complication rate was 4.8%, including 1 case of intraoperative bleeding due to operator inexperience and 2 of a delay in staples falling out. No patient experienced wound infection or excessive foreskin excision. No incision site edema was observed beyond postoperative day 7. All enrolled patients were satisfied with the postoperative penile cosmesis. CONCLUSIONS: The circular cutter with stapled anastomosis for circumcision is a 1-step device that can achieve excellent postoperative results with minimal procedural time. Therefore, it has the potential to enable the performance of circumcision as a rapid turnover bedside procedure.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Circuncisão Masculina Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Circuncisão Masculina Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2014 Tipo de documento: Article